Quantifying temporal dynamics of greenhouse gas emissions in lake mesocosms: Deployment of a low‐cost measurement system

Abstract Greenhouse gas (GHG) emissions from freshwater ecosystems contribute significantly to global carbon budgets, yet they remain poorly constrained due to limited high‐frequency measurements. We tested a low‐cost, high‐frequency GHG measurement system in a long‐term mesocosm experiment in Lemming, Denmark, over a 7‐month period, focusing on CO 2 and CH 4 fluxes. We deployed a methodology for calculating CH 4 diffusive fluxes using high‐frequency sensor data and tested the effects of sampling intervals on emission upscaling. Our findings reveal substantial temporal variability in GHG emissions, particularly for CH 4 , with ebullitive fluxes dominating and exhibiting large variation. Pronounced diurnal fluctuations were also observed for CO 2 and diffusive CH 4 fluxes, whereas ebullitive CH 4 emissions showed no significant diurnal pattern. Relying solely on daytime measurements led to a significant overestimation of overall CO 2 fluxes and CH 4 diffusive fluxes. Resampling data at lower frequency showed that reduced sampling frequency leads to an underestimation of total emissions, especially for CH 4 ebullitive fluxes. Increasing the sampling interval from daily to monthly markedly increased uncertainty, while weekly sampling better captured overall GHG flux patterns and reduced the uncertainty compared with more infrequent sampling. These results underscore the value of high‐frequency GHG measurements in capturing both diurnal and seasonal variations, improving the accuracy of flux estimates, and reducing uncertainties in upscaling emission. We emphasize the need to optimize sampling intervals and incorporate diurnal cycle measurements to enhance the accuracy and reliability of freshwater GHG assessments.

Authors

Institutions

Publication Details

Journal
Limnology and Oceanography Methods
Published
2026-05-08
DOI
https://doi.org/10.1002/lom3.70060
Primary Topic
Marine and coastal ecosystems
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantifying temporal dynamics of greenhouse gas emissions in lake mesocosms: Deployment of a low‐cost measurement system

Robert Ladwig, Claus Melvad, Thomas A. Davidson, Tuba Bucak et al.
Limnology and Oceanography Methods
Marine and coastal ecosystems
article

Quantifying temporal dynamics of greenhouse gas emissions in lake mesocosms: Deployment of a low‐cost measurement system

Robert Ladwig, Claus Melvad, Thomas A. Davidson, Tuba Bucak, Mikhail Mastepanov, Eti Ester Levi, Jianming Deng
article en

Abstract

Abstract Greenhouse gas (GHG) emissions from freshwater ecosystems contribute significantly to global carbon budgets, yet they remain poorly constrained due to limited high‐frequency measurements. We tested a low‐cost, high‐frequency GHG measurement system in a long‐term mesocosm experiment in Lemming, Denmark, over a 7‐month period, focusing on CO 2 and CH 4 fluxes. We deployed a methodology for calculating CH 4 diffusive fluxes using high‐frequency sensor data and tested the effects of sampling intervals on emission upscaling. Our findings reveal substantial temporal variability in GHG emissions, particularly for CH 4 , with ebullitive fluxes dominating and exhibiting large variation. Pronounced diurnal fluctuations were also observed for CO 2 and diffusive CH 4 fluxes, whereas ebullitive CH 4 emissions showed no significant diurnal pattern. Relying solely on daytime measurements led to a significant overestimation of overall CO 2 fluxes and CH 4 diffusive fluxes. Resampling data at lower frequency showed that reduced sampling frequency leads to an underestimation of total emissions, especially for CH 4 ebullitive fluxes. Increasing the sampling interval from daily to monthly markedly increased uncertainty, while weekly sampling better captured overall GHG flux patterns and reduced the uncertainty compared with more infrequent sampling. These results underscore the value of high‐frequency GHG measurements in capturing both diurnal and seasonal variations, improving the accuracy of flux estimates, and reducing uncertainties in upscaling emission. We emphasize the need to optimize sampling intervals and incorporate diurnal cycle measurements to enhance the accuracy and reliability of freshwater GHG assessments.

Limnology and Oceanography Methods
Chinese Academy of Sciences (CN), Aarhus University (DK), Danish Institute for Quality and Accreditation in Healthcare (DK), Nanjing Institute of Geography and Limnology (CN), Oulu University of Applied Sciences (FI), University of Oulu (FI)
National Natural Science Foundation of China, Aarhus Universitets Forskningsfond, Carlsbergfondet, H2020 European Research Council, H2020 Research Infrastructures
Openalex Percentile: Top 5%
Marine and coastal ecosystems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.