Corrosion-Related Failures in Modular Total Knee Arthroplasty: A Narrative Review of Rare Published Clinical Cases.

» Corrosion at modular junctions is a well-known cause of failure in primary and revision total hip arthroplasty, but it is underrecognized in modular total knee arthroplasty (TKA) despite the potential to cause clinically significant implant failure. » Although descriptions vary throughout case reports, mechanically assisted crevice corrosion (MACC) appears to be the underlying failure mechanism at these modular TKA junctions, as is seen in femoral component modularity in total hip arthroplasty (THA). » Adverse local tissue reactions (ALTR) and fatigue fractures can occur even in well-fixed TKA implants and can be difficult to detect clinically or radiographically. » The femoral component in constrained or rotating-hinge designs may be at higher risk for corrosion-related complications. » An appropriate index of suspicion, improved surveillance protocols, advanced imaging, and design innovations are needed to aid diagnosis, mitigate future failures, and guide revision strategies.

Authors

Institutions

Publication Details

Journal
PubMed
Published
2026-05-08
DOI
https://doi.org/10.2106/jbjs.oa.26.00005
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion-Related Failures in Modular Total Knee Arthroplasty: A Narrative Review of Rare Published Clinical Cases.

Lisa Follett, Amy Lu, Aymen Alqazzaz, Krithi Pachipala et al.
PubMed
Orthopaedic implants and arthroplasty
article

Corrosion-Related Failures in Modular Total Knee Arthroplasty: A Narrative Review of Rare Published Clinical Cases.

Lisa Follett, Amy Lu, Aymen Alqazzaz, Krithi Pachipala, Joshua J Jacobs, H John Cooper
article en

Abstract

» Corrosion at modular junctions is a well-known cause of failure in primary and revision total hip arthroplasty, but it is underrecognized in modular total knee arthroplasty (TKA) despite the potential to cause clinically significant implant failure. » Although descriptions vary throughout case reports, mechanically assisted crevice corrosion (MACC) appears to be the underlying failure mechanism at these modular TKA junctions, as is seen in femoral component modularity in total hip arthroplasty (THA). » Adverse local tissue reactions (ALTR) and fatigue fractures can occur even in well-fixed TKA implants and can be difficult to detect clinically or radiographically. » The femoral component in constrained or rotating-hinge designs may be at higher risk for corrosion-related complications. » An appropriate index of suspicion, improved surveillance protocols, advanced imaging, and design innovations are needed to aid diagnosis, mitigate future failures, and guide revision strategies.

PubMedVol. 11(2)
Rush University Medical Center (US), Cornell University (US), Columbia University Irving Medical Center (US), Weill Cornell Medicine (US)
Openalex Percentile: Top 6%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.