0691 Long PSG-MSLT Improves Diagnostic Accuracy for Severe Idiopathic Hypersomnia Symptoms Across Multi-center Cohort

Abstract Introduction Diagnosing Idiopathic Hypersomnia (IH) remains challenging due to the limited feasibility and accuracy of objective tests specified in the ICSD-3TR. In the literature, the multiple sleep latency test (MSLT), using a cutoff of mean sleep latency (MSL) ≤ 8 minutes, demonstrates poor validity and reliability. Actigraphy-based determination of total sleep time (TST) ≥ 11 hours is hindered by inaccurate detection of daytime sleep. Twenty-four-hour polysomnography (PSG) can more precisely assess sleep duration but is rarely feasible in routine clinical settings. To address these limitations, we evaluated a modified “long PSG-MSLT,” hypothesizing that aggregated TST across the extended protocol would more accurately identify individuals with severe IH symptoms than MSL alone. Methods The long PSG-MSLT was implemented for clinical IH evaluation across five U.S. sleep centers. Patients aged 15–45 years completed an extended overnight PSG (approximately 9–10 PM to 10 AM) followed by a four-nap MSLT, with the final nap allowing up to 60 minutes of sleep or natural awakening. Diagnostic accuracy for detecting severe IH symptoms—defined as Idiopathic Hypersomnia Severity Scale (IHSS) ≥ 26—was assessed using receiver-operating characteristic (ROC) analysis. Results A total of 112 individuals (mean age 24.7 ± 7.4 years; 62.2% female) completed testing; 84% scored IHSS ≥ 26. MSL demonstrated non-significant diagnostic accuracy (AUC = 0.66; 95% CI 0.53–0.79; p = 0.06), while aggregated TST showed significant accuracy (AUC = 0.79; 95% CI 0.69–0.90; p < 0.0005). An MSL ≤ 8 minutes showed poor sensitivity (23.2%) but high specificity (92.9%) and did not differentiate IHSS severity (Fisher’s exact p = 0.29). Combining MSL ≤ 8 minutes and/or total sleep time ≥ 11 hours metrics improved sensitivity to 51% while maintaining high specificity (92.9%) and significantly distinguished IHSS severity groups (Fisher’s exact p = 0.002). Conclusion The ICSD-3TR criterion of MSL ≤ 8 minutes lacks diagnostic accuracy for identifying individuals with severe IH symptoms and fails to differentiate symptom severity. The modified long PSG-MSLT provides a clinically feasible and more accurate diagnostic approach by capturing increased sleep need—a core feature of many people with IH. Support (if any) NIH NINDS 5R61NS130215-02, PI Kiran Maski MD MPH

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0690
Primary Topic
Sleep and related disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0691 Long PSG-MSLT Improves Diagnostic Accuracy for Severe Idiopathic Hypersomnia Symptoms Across Multi-center Cohort

Kelley Dunham, Jennifer Worhach, Milena Pavlova, Neil Dhruva et al.
SLEEP
Sleep and related disorders
article

0691 Long PSG-MSLT Improves Diagnostic Accuracy for Severe Idiopathic Hypersomnia Symptoms Across Multi-center Cohort

Kelley Dunham, Jennifer Worhach, Milena Pavlova, Neil Dhruva, Tyler Blake, Grace Wang, Lynn Trotti, Maya Baruch, Robert Thomas, Kiran Maski, Bo Zhang, Paramjai Sandhu, Sanford Auerback
article en

Abstract

Abstract Introduction Diagnosing Idiopathic Hypersomnia (IH) remains challenging due to the limited feasibility and accuracy of objective tests specified in the ICSD-3TR. In the literature, the multiple sleep latency test (MSLT), using a cutoff of mean sleep latency (MSL) ≤ 8 minutes, demonstrates poor validity and reliability. Actigraphy-based determination of total sleep time (TST) ≥ 11 hours is hindered by inaccurate detection of daytime sleep. Twenty-four-hour polysomnography (PSG) can more precisely assess sleep duration but is rarely feasible in routine clinical settings. To address these limitations, we evaluated a modified “long PSG-MSLT,” hypothesizing that aggregated TST across the extended protocol would more accurately identify individuals with severe IH symptoms than MSL alone. Methods The long PSG-MSLT was implemented for clinical IH evaluation across five U.S. sleep centers. Patients aged 15–45 years completed an extended overnight PSG (approximately 9–10 PM to 10 AM) followed by a four-nap MSLT, with the final nap allowing up to 60 minutes of sleep or natural awakening. Diagnostic accuracy for detecting severe IH symptoms—defined as Idiopathic Hypersomnia Severity Scale (IHSS) ≥ 26—was assessed using receiver-operating characteristic (ROC) analysis. Results A total of 112 individuals (mean age 24.7 ± 7.4 years; 62.2% female) completed testing; 84% scored IHSS ≥ 26. MSL demonstrated non-significant diagnostic accuracy (AUC = 0.66; 95% CI 0.53–0.79; p = 0.06), while aggregated TST showed significant accuracy (AUC = 0.79; 95% CI 0.69–0.90; p < 0.0005). An MSL ≤ 8 minutes showed poor sensitivity (23.2%) but high specificity (92.9%) and did not differentiate IHSS severity (Fisher’s exact p = 0.29). Combining MSL ≤ 8 minutes and/or total sleep time ≥ 11 hours metrics improved sensitivity to 51% while maintaining high specificity (92.9%) and significantly distinguished IHSS severity groups (Fisher’s exact p = 0.002). Conclusion The ICSD-3TR criterion of MSL ≤ 8 minutes lacks diagnostic accuracy for identifying individuals with severe IH symptoms and fails to differentiate symptom severity. The modified long PSG-MSLT provides a clinically feasible and more accurate diagnostic approach by capturing increased sleep need—a core feature of many people with IH. Support (if any) NIH NINDS 5R61NS130215-02, PI Kiran Maski MD MPH

SLEEPVol. 49(Supplement_1)
Brigham and Women's Hospital (US), Boston Medical Center (US), Boston Children's Hospital (US), Emory University (US), Hadassah Medical Center (IL), NephroCare (ES), Boston Children's Museum (US)
No poverty
Openalex Percentile: Top 5%
Sleep and related disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.