Pacemaker Lead Endocarditis Secondary to Staphylococcus aureus Infection From a Flash Glucose Monitor Insertion Site in a Patient With Type 1 Diabetes: A Case Report

Flash glucose monitoring (FGM) systems are widely used in diabetes care, although cutaneous complications remain uncommon. However, FGM insertion-site infections can serve as a portal for Staphylococcus aureus, potentially leading to systemic complications in high-risk patients. We report the case of a 46-year-old man with poorly controlled type 1 diabetes who presented with fever, confusion, and cellulitis at an FGM site. Cultures confirmed persistent S. aureus bacteremia. Imaging revealed deep glenohumeral joint infection requiring surgical washout. Despite an initially normal transthoracic echocardiogram, persistent bacteremia prompted transesophageal echocardiography, which demonstrated a pacemaker lead vegetation. He underwent complete device extraction and received prolonged IV flucloxacillin. This case highlights the potential for FGM-site infections to progress to septic arthritis and pacemaker lead infective endocarditis, emphasizing early recognition and aggressive management.

Authors

Publication Details

Journal
Cureus
Published
2026-05-08
DOI
https://doi.org/10.7759/cureus.108483
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pacemaker Lead Endocarditis Secondary to Staphylococcus aureus Infection From a Flash Glucose Monitor Insertion Site in a Patient With Type 1 Diabetes: A Case Report

Zahra Parsian, Hamza Al-Hayek, Sanjalee Dalpathadu, Kyaw Linn
Cureus
Cardiac pacing and defibrillation studies
article

Pacemaker Lead Endocarditis Secondary to Staphylococcus aureus Infection From a Flash Glucose Monitor Insertion Site in a Patient With Type 1 Diabetes: A Case Report

Zahra Parsian, Hamza Al-Hayek, Sanjalee Dalpathadu, Kyaw Linn
article en

Abstract

Flash glucose monitoring (FGM) systems are widely used in diabetes care, although cutaneous complications remain uncommon. However, FGM insertion-site infections can serve as a portal for Staphylococcus aureus, potentially leading to systemic complications in high-risk patients. We report the case of a 46-year-old man with poorly controlled type 1 diabetes who presented with fever, confusion, and cellulitis at an FGM site. Cultures confirmed persistent S. aureus bacteremia. Imaging revealed deep glenohumeral joint infection requiring surgical washout. Despite an initially normal transthoracic echocardiogram, persistent bacteremia prompted transesophageal echocardiography, which demonstrated a pacemaker lead vegetation. He underwent complete device extraction and received prolonged IV flucloxacillin. This case highlights the potential for FGM-site infections to progress to septic arthritis and pacemaker lead infective endocarditis, emphasizing early recognition and aggressive management.

Cureus
Good health and well-being
Openalex Percentile: Top 6%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.