0600 Identifying Responders to Mandibular Advancement Devices in ADVANCE: A Subgroup Analysis in Prosomnus Devices

Abstract Introduction Obstructive sleep apnea (OSA) is common and harmful, yet difficult to treat. Continuous positive airway pressure is often limited by adherence, while mandibular advancement devices (MAD) are more tolerable but work well only in some patients. Identifying mechanistic subgroups with the greatest likelihood of benefit could enable MAD as first-line therapy in selected individuals. Using pooled data from six studies, we recently developed an endotype-based prediction model. Because response may vary by device, this presentation examines outcomes specifically with Prosomnus devices (a sponsor of FLOSAT and Praxis). Methods The ADVANCE consortium (US, Belgium, Australia, France) pooled individual patient data from six MAD studies (PROMAD, OASSC, UGAMAD, MADOx, FLOSAT, Praxis) comprising 281 patients with baseline apnea-hypopnea index (AHI) > 10 events/hr. In the parent study, patients in the strong-response endotype—characterized by lower loop gain, higher AHI, younger age, lower BMI, and greater sleep depth—exhibited a 62 [54, 69] %reduction in AHI (N=55), stronger than the 37 [26, 48] %reduction (P=0.001) seen in the remaining patients (moderate-response endotype, N=35). Here we reassessed outcomes by subgroup in patients using Prosomnus devices. Results were presented for all patients (N=119, development+validation), and the validation subset (N=58; 33% of FLOSAT; plus Praxis, collected prospectively for validation). Linear regression compared the %reduction in AHI between groups. The primary test was the subgroup difference in the validation sample. Results Participant characteristics: 94M:25F, median[IQR] age=54[44-62] years, BMI=28[26-31] kg/m2, AHI=25[18-34] events/hr. In the overall sample, patients in the strong-response endotype (N=64) exhibited a 70% [64, 75] reduction in AHI, which was stronger than the 53% [46, 59] reduction in the moderate-response endotype (N=55). In validation: the strong-response endotype (N=29) exhibited a 68% [58, 76] reduction in AHI, which was stronger than 51% [39, 62] in the moderate-response endotype (N=29). The therapeutic difference was 17% [92.3, 31] (P=0.026), exceeding the minimal clinically-important difference (15%). Conclusion The strong-response endotype subgroup—characterized by lower loop gain, higher AHI, younger age, lower BMI, and greater sleep depth—achieved profound OSA improvements with Prosomnus MAD devices, knowledge which may facilitate a precision model of care employing MAD as a first-line intervention in selected patients. Support (if any) 5R01HL102321

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0599
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0600 Identifying Responders to Mandibular Advancement Devices in ADVANCE: A Subgroup Analysis in Prosomnus Devices

Sara Op de Beeck, Bradley Edwards, Reza Radmand, João Luiz Gomes Carneiro Monteiro et al.
SLEEP
Obstructive Sleep Apnea Research
article

0600 Identifying Responders to Mandibular Advancement Devices in ADVANCE: A Subgroup Analysis in Prosomnus Devices

Sara Op de Beeck, Bradley Edwards, Reza Radmand, João Luiz Gomes Carneiro Monteiro, Daniel Vena, Scott Sands, O Vanderveken, Jean-Louis Pepin, Ali Azarbarzin, Andrew Wellman
article en

Abstract

Abstract Introduction Obstructive sleep apnea (OSA) is common and harmful, yet difficult to treat. Continuous positive airway pressure is often limited by adherence, while mandibular advancement devices (MAD) are more tolerable but work well only in some patients. Identifying mechanistic subgroups with the greatest likelihood of benefit could enable MAD as first-line therapy in selected individuals. Using pooled data from six studies, we recently developed an endotype-based prediction model. Because response may vary by device, this presentation examines outcomes specifically with Prosomnus devices (a sponsor of FLOSAT and Praxis). Methods The ADVANCE consortium (US, Belgium, Australia, France) pooled individual patient data from six MAD studies (PROMAD, OASSC, UGAMAD, MADOx, FLOSAT, Praxis) comprising 281 patients with baseline apnea-hypopnea index (AHI) > 10 events/hr. In the parent study, patients in the strong-response endotype—characterized by lower loop gain, higher AHI, younger age, lower BMI, and greater sleep depth—exhibited a 62 [54, 69] %reduction in AHI (N=55), stronger than the 37 [26, 48] %reduction (P=0.001) seen in the remaining patients (moderate-response endotype, N=35). Here we reassessed outcomes by subgroup in patients using Prosomnus devices. Results were presented for all patients (N=119, development+validation), and the validation subset (N=58; 33% of FLOSAT; plus Praxis, collected prospectively for validation). Linear regression compared the %reduction in AHI between groups. The primary test was the subgroup difference in the validation sample. Results Participant characteristics: 94M:25F, median[IQR] age=54[44-62] years, BMI=28[26-31] kg/m2, AHI=25[18-34] events/hr. In the overall sample, patients in the strong-response endotype (N=64) exhibited a 70% [64, 75] reduction in AHI, which was stronger than the 53% [46, 59] reduction in the moderate-response endotype (N=55). In validation: the strong-response endotype (N=29) exhibited a 68% [58, 76] reduction in AHI, which was stronger than 51% [39, 62] in the moderate-response endotype (N=29). The therapeutic difference was 17% [92.3, 31] (P=0.026), exceeding the minimal clinically-important difference (15%). Conclusion The strong-response endotype subgroup—characterized by lower loop gain, higher AHI, younger age, lower BMI, and greater sleep depth—achieved profound OSA improvements with Prosomnus MAD devices, knowledge which may facilitate a precision model of care employing MAD as a first-line intervention in selected patients. Support (if any) 5R01HL102321

SLEEPVol. 49(Supplement_1)
Brigham and Women's Hospital (US), Harvard University (US), University of Antwerp (BE), Inserm (FR), Centre Hospitalier Universitaire de Grenoble (FR), Australian Regenerative Medicine Institute (AU), Harvard University Press (US), Grenoble Institute of Neurosciences (FR), Monash University (AU), Université Grenoble Alpes (FR)
Openalex Percentile: Top 7%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.