0581 Validation of Total Sleep Time and Apnea Hypopnea Index from EEG and Saturation Measurements of Full Night Wearable Dry Printed Electrode System

Abstract Introduction Quantitative assessment of sleep is essential for diagnosing sleep disorders and evaluating treatment efficacy. Polysomnography (PSG), in a laboratory setting, is considered the gold standard for objective sleep assessment, however PSG is resource-intensive, expensive, and can disrupt a patient's normal sleep pattern. Wearable devices based on dry-printed electrode arrays have emerged as a practical and accessible promising alternative to traditional PSG for skin electrophysiology during sleep. Dry printed electrodes offer several advantages, such as signal stability, ease of application especially in the home environment setting, and patient convenience. While wearable devices offer a convenient and simple solution, their accuracy, and particularly concerning metrics like Total Sleep Time (TST) and Apnea Hypopnea Index (AHI), must be validated against the established gold-standard in-laboratory polysomnography. In previous studies we showed accuracy to polysomnography signals and basic sleep stages scoring. This study compares TST and AHI measurements obtained from manual scoring from the tested wearable device with those derived from full PSG. Methods This validation study included 10 healthy subjects as a preparation for additional 40 subjects with suspected sleep disorders. Each subject was connected to both systems simultaneously, the PSG and the tested system. The subjects were monitored during a complete night in a sleep facility. The tested system comprises two novel multi-electrode patches for face and chest including EEG, EOG, EMG, ECG, SpO2 wrist sensor, a wireless recording device, and a mobile application. The raw data from both systems scored manually by the same scorer and compared for validation purposes. The Oxygen Desaturation Index (ODI) scored manually from the SpO2 of the tested device and was compared to the AHI of the PSG. Results The agreement between the TST values of both systems ranged from 93% to 98.8% with an average of 96.5%. Comparing the Oxygen Desaturation Index (ODI) to the AHI of the full PSG shows good agreement with higher correlation in higher values of AHI. Conclusion The parameters agreement of the healthy subjects between the systems is very successful and promising toward the challenge of acquiring high quality medical grade signals at home environment during full night of sleep. Support (if any)

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0580
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0581 Validation of Total Sleep Time and Apnea Hypopnea Index from EEG and Saturation Measurements of Full Night Wearable Dry Printed Electrode System

Daniel Possti, Yael Hanein, Shani Oz, Deganit Barak‐Shinar et al.
SLEEP
Non-Invasive Vital Sign Monitoring
article

0581 Validation of Total Sleep Time and Apnea Hypopnea Index from EEG and Saturation Measurements of Full Night Wearable Dry Printed Electrode System

Daniel Possti, Yael Hanein, Shani Oz, Deganit Barak‐Shinar, Katharina Lederer, Rona Haker, Ingo Fietze, Thomas Penzel
article en

Abstract

Abstract Introduction Quantitative assessment of sleep is essential for diagnosing sleep disorders and evaluating treatment efficacy. Polysomnography (PSG), in a laboratory setting, is considered the gold standard for objective sleep assessment, however PSG is resource-intensive, expensive, and can disrupt a patient's normal sleep pattern. Wearable devices based on dry-printed electrode arrays have emerged as a practical and accessible promising alternative to traditional PSG for skin electrophysiology during sleep. Dry printed electrodes offer several advantages, such as signal stability, ease of application especially in the home environment setting, and patient convenience. While wearable devices offer a convenient and simple solution, their accuracy, and particularly concerning metrics like Total Sleep Time (TST) and Apnea Hypopnea Index (AHI), must be validated against the established gold-standard in-laboratory polysomnography. In previous studies we showed accuracy to polysomnography signals and basic sleep stages scoring. This study compares TST and AHI measurements obtained from manual scoring from the tested wearable device with those derived from full PSG. Methods This validation study included 10 healthy subjects as a preparation for additional 40 subjects with suspected sleep disorders. Each subject was connected to both systems simultaneously, the PSG and the tested system. The subjects were monitored during a complete night in a sleep facility. The tested system comprises two novel multi-electrode patches for face and chest including EEG, EOG, EMG, ECG, SpO2 wrist sensor, a wireless recording device, and a mobile application. The raw data from both systems scored manually by the same scorer and compared for validation purposes. The Oxygen Desaturation Index (ODI) scored manually from the SpO2 of the tested device and was compared to the AHI of the PSG. Results The agreement between the TST values of both systems ranged from 93% to 98.8% with an average of 96.5%. Comparing the Oxygen Desaturation Index (ODI) to the AHI of the full PSG shows good agreement with higher correlation in higher values of AHI. Conclusion The parameters agreement of the healthy subjects between the systems is very successful and promising toward the challenge of acquiring high quality medical grade signals at home environment during full night of sleep. Support (if any)

SLEEPVol. 49(Supplement_1)
Tel Aviv University (IL), Xavier School (PH), Sleep Research Society (US), Charité - Universitätsmedizin Berlin (DE)
Openalex Percentile: Top 8%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.