0975 Beyond ECG: Robust Deep Learning-Enabled Atrial Fibrillation Detection in HSATs with PPG

Abstract Introduction Atrial fibrillation (AFib) is a prevalent and often underdiagnosed comorbidity in patients with obstructive sleep apnea (OSA). Photoplethysmography (PPG) is widely available in PSG and home sleep apnea tests (HSAT), yet detection of AFib and atrial flutter (AFL) typically relies on electrocardiography (ECG). We developed and evaluated a deep learning model to detect AF events (AFib and AFL combined) from PPG signals, offering a scalable solution to implement high-accuracy, routine detection within large clinical sleep cohorts. Methods A total of N=10,767 studies with simultaneous ECG and PPG were randomly sampled from a large clinical PSG/HSAT database. Sampling was stratified uniformly across AFib burden to construct balanced training (N=7,752), validation (N=1,938), and test (N=1,077) datasets. AFib burden was estimated using a validated open-source ECG model and defined as the percentage of segments classified as AFib. Definitive AF labels were derived from a validated ECG analysis algorithm applied to a single-lead ECG II.​​ A deep learning model was trained exclusively on PPG signals, and performance was evaluated on a per-epoch (30-second) basis on the test set. A total of 67,023 (7.5%) of the 30-second epochs in the test sample group were excluded due to insufficient PPG signal quality or artifacts. Results The PPG-based deep learning model achieved strong per-epoch AF (AFib/AFL) classification performance on the test dataset of 1,077 patients, which comprised 656,651 AF epochs and 173,579 non-AF epochs. The model achieved a ROC-AUC of 0.968, sensitivity of 97.4%, and specificity of 91.3%. The corresponding positive predictive value (PPV) was 97.7%, and negative predictive value (NPV) was 90.3%. Conclusion The deep learning PPG model demonstrated robust detection of AF, achieving performance comparable to the gold-standard of ECG for AFib diagnosis. These findings highlight the potential to integrate automated AF detection into existing HSAT and PSG workflows, enabling scalable, high-accuracy arrhythmia screening in patients undergoing sleep studies without the need for additional hardware. Support (if any)

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0974
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0975 Beyond ECG: Robust Deep Learning-Enabled Atrial Fibrillation Detection in HSATs with PPG

Nathaniel Watson, Sam Rusk, Nick Glattard, Tom Vanasse et al.
SLEEP
Obstructive Sleep Apnea Research
article

0975 Beyond ECG: Robust Deep Learning-Enabled Atrial Fibrillation Detection in HSATs with PPG

Nathaniel Watson, Sam Rusk, Nick Glattard, Tom Vanasse, Fred Turkington, Matt Sprague, Jan Wodnicki, Krishna Sundar, Yoav Nygate, Chris Fernandez
article en

Abstract

Abstract Introduction Atrial fibrillation (AFib) is a prevalent and often underdiagnosed comorbidity in patients with obstructive sleep apnea (OSA). Photoplethysmography (PPG) is widely available in PSG and home sleep apnea tests (HSAT), yet detection of AFib and atrial flutter (AFL) typically relies on electrocardiography (ECG). We developed and evaluated a deep learning model to detect AF events (AFib and AFL combined) from PPG signals, offering a scalable solution to implement high-accuracy, routine detection within large clinical sleep cohorts. Methods A total of N=10,767 studies with simultaneous ECG and PPG were randomly sampled from a large clinical PSG/HSAT database. Sampling was stratified uniformly across AFib burden to construct balanced training (N=7,752), validation (N=1,938), and test (N=1,077) datasets. AFib burden was estimated using a validated open-source ECG model and defined as the percentage of segments classified as AFib. Definitive AF labels were derived from a validated ECG analysis algorithm applied to a single-lead ECG II.​​ A deep learning model was trained exclusively on PPG signals, and performance was evaluated on a per-epoch (30-second) basis on the test set. A total of 67,023 (7.5%) of the 30-second epochs in the test sample group were excluded due to insufficient PPG signal quality or artifacts. Results The PPG-based deep learning model achieved strong per-epoch AF (AFib/AFL) classification performance on the test dataset of 1,077 patients, which comprised 656,651 AF epochs and 173,579 non-AF epochs. The model achieved a ROC-AUC of 0.968, sensitivity of 97.4%, and specificity of 91.3%. The corresponding positive predictive value (PPV) was 97.7%, and negative predictive value (NPV) was 90.3%. Conclusion The deep learning PPG model demonstrated robust detection of AF, achieving performance comparable to the gold-standard of ECG for AFib diagnosis. These findings highlight the potential to integrate automated AF detection into existing HSAT and PSG workflows, enabling scalable, high-accuracy arrhythmia screening in patients undergoing sleep studies without the need for additional hardware. Support (if any)

SLEEPVol. 49(Supplement_1)
University of Washington (US), University of California Davis Medical Center (US)
Quality Education
Openalex Percentile: Top 7%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.