1318 Hypoglossal Nerve Stimulation Lead with Recurrent Extrusion

Abstract Introduction Hypoglossal nerve stimulation (HNS) is increasingly being utilized for treatment of obstructive sleep apnea (OSA) in patients with intolerance to positive airway pressure. One HNS device consists of an implanted pulse generator, a respiratory sensing lead, and stimulation lead. Lead migration, misalignment, and extrusion have been reported. We describe a case of recurrent stimulation lead extrusion. Report of case(s) A 54-year-old man with severe OSA (apnea-hypopnea index 44.6/hour), shift work disorder, and hypertension underwent HNS implantation in March 2024. He had an uncomplicated post-operative course and HNS activation. He followed up with sleep medicine and was given instructions for continued amplitude adjustments. He did not follow up as scheduled, instead re-presenting in March 2025 for evaluation of progressive neck fullness to otolaryngology clinic. On physical examination, it was found that the stimulation lead was extruding 2-3 cm out of his neck without signs of infection. The following day, he had surgical revision, including freeing the lead wire and tucking it under the submandibular gland, suturing the gland over the wire, creating a sterno-hyoid flap and suturing that over the gland and wire, closing of the platysma over the strap muscle flap, and closing the skin in multiple layers. Intraoperative testing indicated normal function. The patient presented for follow-up to sleep medicine six months post-revision with concerns of wire extruding out his neck again. Exam revealed a visible wire at his neck incision under a thin layer of skin without signs of infection. HNS was functioning, but review of data showed continued sporadic usage from the first day post-revision with titration just below his upper limit at 1.9V. He was referred back to otolaryngology for recurrent lead extrusion, and the device was subsequently explanted in October 2025. Conclusion HNS lead extrusion has been reported to be a rare complication. The reason for the recurrent lead extrusion was not known in this case but did not appear to be related to an infection. Management with lead revision, lead replacement, or HNS removal does not have robust data. However, if lead revision or replacement is chosen for management, the patient should be informed that recurrence is possible. Support (if any)

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.1317
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1318 Hypoglossal Nerve Stimulation Lead with Recurrent Extrusion

Arminder Johal, Anurag Reddy, Milan Patel, Noah Parker et al.
SLEEP
Obstructive Sleep Apnea Research
article

1318 Hypoglossal Nerve Stimulation Lead with Recurrent Extrusion

Arminder Johal, Anurag Reddy, Milan Patel, Noah Parker, Stephanie Stahl
article en

Abstract

Abstract Introduction Hypoglossal nerve stimulation (HNS) is increasingly being utilized for treatment of obstructive sleep apnea (OSA) in patients with intolerance to positive airway pressure. One HNS device consists of an implanted pulse generator, a respiratory sensing lead, and stimulation lead. Lead migration, misalignment, and extrusion have been reported. We describe a case of recurrent stimulation lead extrusion. Report of case(s) A 54-year-old man with severe OSA (apnea-hypopnea index 44.6/hour), shift work disorder, and hypertension underwent HNS implantation in March 2024. He had an uncomplicated post-operative course and HNS activation. He followed up with sleep medicine and was given instructions for continued amplitude adjustments. He did not follow up as scheduled, instead re-presenting in March 2025 for evaluation of progressive neck fullness to otolaryngology clinic. On physical examination, it was found that the stimulation lead was extruding 2-3 cm out of his neck without signs of infection. The following day, he had surgical revision, including freeing the lead wire and tucking it under the submandibular gland, suturing the gland over the wire, creating a sterno-hyoid flap and suturing that over the gland and wire, closing of the platysma over the strap muscle flap, and closing the skin in multiple layers. Intraoperative testing indicated normal function. The patient presented for follow-up to sleep medicine six months post-revision with concerns of wire extruding out his neck again. Exam revealed a visible wire at his neck incision under a thin layer of skin without signs of infection. HNS was functioning, but review of data showed continued sporadic usage from the first day post-revision with titration just below his upper limit at 1.9V. He was referred back to otolaryngology for recurrent lead extrusion, and the device was subsequently explanted in October 2025. Conclusion HNS lead extrusion has been reported to be a rare complication. The reason for the recurrent lead extrusion was not known in this case but did not appear to be related to an infection. Management with lead revision, lead replacement, or HNS removal does not have robust data. However, if lead revision or replacement is chosen for management, the patient should be informed that recurrence is possible. Support (if any)

SLEEPVol. 49(Supplement_1)
University School (US), Indiana University School of Medicine, Indiana University (US)
Openalex Percentile: Top 6%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.