Effects of Fin Length on Frosting and Defrosting Characteristics of Small-Diameter Copper Tube-Fin Heat Exchangers

Frost buildup on copper tube-fin heat exchangers reduces their performance in cold, humid conditions. Fin length plays a key role in balancing heat transfer and frost resistance. This study experimentally examines how fin length affects thermal and frosting behavior. Four heat exchangers with fin lengths of 15.1mm, 18.53mm, 20.3mm, and 23.5mm were tested at 2∘C/ 1∘C dry-bulb/wet-bulb air temperature and −6∘C coolant temperature under constant static pressure. Results show that longer fins increase total heat transfer—peak capacity rose from 512W to 566W—but reduce heat transfer per unit area by about 30%. Operating time before defrosting increased by 30.6%, from 45.7min to 59.6min, due to lower frost density. Total frost mass grew, but unit-area frost decreased by 12.7%. During defrosting, longer fins achieved greater absolute airflow recovery (from 195 to 213 m3/h), though defrosting efficiency per gram of frost declined. Short fins ( 15mm) suit space-limited systems needing high surface efficiency. Long fins ( 23mm) benefit large systems requiring long run times and strong post-defrost performance. Medium lengths ( 17mm to 20mm) offer a practical balance for general use. These findings support better heat exchanger design in frost-prone applications.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-05-08
DOI
https://doi.org/10.3390/app16104663
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Fin Length on Frosting and Defrosting Characteristics of Small-Diameter Copper Tube-Fin Heat Exchangers

Wenbin Cui, Dalong Liang
Applied Sciences
Heat Transfer and Optimization
article

Effects of Fin Length on Frosting and Defrosting Characteristics of Small-Diameter Copper Tube-Fin Heat Exchangers

Wenbin Cui, Dalong Liang
article en

Abstract

Frost buildup on copper tube-fin heat exchangers reduces their performance in cold, humid conditions. Fin length plays a key role in balancing heat transfer and frost resistance. This study experimentally examines how fin length affects thermal and frosting behavior. Four heat exchangers with fin lengths of 15.1mm, 18.53mm, 20.3mm, and 23.5mm were tested at 2∘C/ 1∘C dry-bulb/wet-bulb air temperature and −6∘C coolant temperature under constant static pressure. Results show that longer fins increase total heat transfer—peak capacity rose from 512W to 566W—but reduce heat transfer per unit area by about 30%. Operating time before defrosting increased by 30.6%, from 45.7min to 59.6min, due to lower frost density. Total frost mass grew, but unit-area frost decreased by 12.7%. During defrosting, longer fins achieved greater absolute airflow recovery (from 195 to 213 m3/h), though defrosting efficiency per gram of frost declined. Short fins ( 15mm) suit space-limited systems needing high surface efficiency. Long fins ( 23mm) benefit large systems requiring long run times and strong post-defrost performance. Medium lengths ( 17mm to 20mm) offer a practical balance for general use. These findings support better heat exchanger design in frost-prone applications.

Applied SciencesVol. 16(10)
Dalian Maritime University (CN)
Affordable and clean energy
Openalex Percentile: Top 9%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effects of Fin Length on Frosting and Defrosting Characteristics of Small-Diameter Copper Tube-Fin Heat Exchangers — Wenbin Cui, Dalong Liang · Applied Sciences (2026) | TGRS Research Map | TGRS