0613 Higher Patient Satisfaction and Therapy Adherence with CPAP vs. ACPAP: Experience in Practice

Abstract Introduction Positive airway pressure (PAP) is the standard for treating obstructive sleep apnea (OSA). However, clinical practice varies regarding initiation strategies: sleep-lab titration followed by fixed continuous PAP (CPAP) vs. auto-CPAP. These secondary analyses expand earlier work examining associations between PAP modality, patient therapy satisfaction (PTS), and initial PAP adherence. Methods This cross-sectional study examined initial adherence/therapy data from two Southeast Michigan durable medical equipment companies for new PAP users (ages ≥ 18) treated for OSA between 01/2022-12/2022. Logistic regression adjusted for age, gender, body mass index (BMI), health insurance, diagnostic testing, median and 95th percentile pressures, diagnostic apnea-hypopnea index (AHI), and propensity scores (calculated using all mentioned variables except pressures settings) was used to examine associations between PAP modality, and PTS (first-month care check-in) and PAP adherence (usage ≥4h for ≥70% of 30 days). Similarly-adjusted linear regression with propensity weighting was used to examine associations between PAP modality and total days PAP used, percent days PAP used ≥4h, and average usage hours (total days, days used, and total hours). Results Among 482 subjects, 50.4% were female. Mean age was 51.9±15.8 years. Median BMI was 33.8±9.0 kg/m2. Compared to auto-CPAP (n=281), CPAP users (n=201) were older (53.6±16.3 vs. 50.6±15.3 years), diagnosed mostly via in-lab polysomnography (70.6% vs. 56.6%), had higher AHI (median 18.0±27.0 vs 11.4±14.1), median leaks (3.2±7.5 vs 1.5±4.6 L/min), and median pressure (9.5±3.4 vs. 7.5±2.1 cmH2O, each p< 0.05). The PTS among CPAP users was 80.1% vs. 67.7% (p=0.02). Adjusted analysis showed associations between PAP modality and PTS (OR=2.2, 95% CI [1.2, 4.0, p=0.01]), and CPAP adherence (OR=2.1, 95% CI [1.1, 3.9, p=0.02]). Adjusted linear regression showed CPAP-treated patients had increased days used (β=11.4, 95% CI [3.7, 19.1] days), percent days with ≥4 h (β=10.6, 95% CI [1.7, 19.5] %), PAP use hours on total days (β=0.7, 95% CI [0.1, 1.4] h), hours on days used (β=0.8, 95% CI [0.2, 1.3] h), and total hours (β=70.6, 95% CI [9.2, 132.0] h). Conclusion This analysis from a quasi-experimental design using real-world data suggests higher patient satisfaction and adherence—by about 120% and 110%, respectively—after titration studies and CPAP use compared with auto-CPAP use. Support (if any)

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0612
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0613 Higher Patient Satisfaction and Therapy Adherence with CPAP vs. ACPAP: Experience in Practice

Neeraj Kaplish, Mark Adams, Ronald Chervin, Aprille Martin et al.
SLEEP
Obstructive Sleep Apnea Research
article

0613 Higher Patient Satisfaction and Therapy Adherence with CPAP vs. ACPAP: Experience in Practice

Neeraj Kaplish, Mark Adams, Ronald Chervin, Aprille Martin, Ronald Gavidia
article en

Abstract

Abstract Introduction Positive airway pressure (PAP) is the standard for treating obstructive sleep apnea (OSA). However, clinical practice varies regarding initiation strategies: sleep-lab titration followed by fixed continuous PAP (CPAP) vs. auto-CPAP. These secondary analyses expand earlier work examining associations between PAP modality, patient therapy satisfaction (PTS), and initial PAP adherence. Methods This cross-sectional study examined initial adherence/therapy data from two Southeast Michigan durable medical equipment companies for new PAP users (ages ≥ 18) treated for OSA between 01/2022-12/2022. Logistic regression adjusted for age, gender, body mass index (BMI), health insurance, diagnostic testing, median and 95th percentile pressures, diagnostic apnea-hypopnea index (AHI), and propensity scores (calculated using all mentioned variables except pressures settings) was used to examine associations between PAP modality, and PTS (first-month care check-in) and PAP adherence (usage ≥4h for ≥70% of 30 days). Similarly-adjusted linear regression with propensity weighting was used to examine associations between PAP modality and total days PAP used, percent days PAP used ≥4h, and average usage hours (total days, days used, and total hours). Results Among 482 subjects, 50.4% were female. Mean age was 51.9±15.8 years. Median BMI was 33.8±9.0 kg/m2. Compared to auto-CPAP (n=281), CPAP users (n=201) were older (53.6±16.3 vs. 50.6±15.3 years), diagnosed mostly via in-lab polysomnography (70.6% vs. 56.6%), had higher AHI (median 18.0±27.0 vs 11.4±14.1), median leaks (3.2±7.5 vs 1.5±4.6 L/min), and median pressure (9.5±3.4 vs. 7.5±2.1 cmH2O, each p< 0.05). The PTS among CPAP users was 80.1% vs. 67.7% (p=0.02). Adjusted analysis showed associations between PAP modality and PTS (OR=2.2, 95% CI [1.2, 4.0, p=0.01]), and CPAP adherence (OR=2.1, 95% CI [1.1, 3.9, p=0.02]). Adjusted linear regression showed CPAP-treated patients had increased days used (β=11.4, 95% CI [3.7, 19.1] days), percent days with ≥4 h (β=10.6, 95% CI [1.7, 19.5] %), PAP use hours on total days (β=0.7, 95% CI [0.1, 1.4] h), hours on days used (β=0.8, 95% CI [0.2, 1.3] h), and total hours (β=70.6, 95% CI [9.2, 132.0] h). Conclusion This analysis from a quasi-experimental design using real-world data suggests higher patient satisfaction and adherence—by about 120% and 110%, respectively—after titration studies and CPAP use compared with auto-CPAP use. Support (if any)

SLEEPVol. 49(Supplement_1)
University of Michigan (US), Tallinn Health Care College (EE), iCons (IT)
Gender equality
Openalex Percentile: Top 7%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.