Performance assessment of TK100 resin for rapid and selective radium retention from environmental waters

Abstract The performance of TK100 resin was evaluated for the rapid and selective preconcentration of 226 Ra for environmental water matrices. High radium uptake was observed in 0.01 M HNO 3 and 0.01 M HCl, with weight distribution ratio above 1000 mL·g −1 , and > 95% retention achieved within 15 min. Adsorption decreased significantly at ≥ 0.1 M HNO 3 and 0.1 M HCl, with D w values decreasing from the order of 10 3 to 10 mL·g −1 . A similar decline was observed at high salinity, defining the operational matrix limits. Column tests confirmed that > 90% of 226 Ra was eluted with 10–15 mL of 0.1 M acid (HNO 3 , HCl). These findings demonstrate the suitability of TK100 for routine preconcentration of 226 Ra in routine environmental monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Radioanalytical and Nuclear Chemistry
Published
2026-05-08
DOI
https://doi.org/10.1007/s10967-026-10913-0
Primary Topic
Chemical Synthesis and Characterization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance assessment of TK100 resin for rapid and selective radium retention from environmental waters

C. Aguilar, M. Gongora, F. Borrull, J. Martínez et al.
Journal of Radioanalytical and Nuclear Chemistry
Chemical Synthesis and Characterization
article

Performance assessment of TK100 resin for rapid and selective radium retention from environmental waters

C. Aguilar, M. Gongora, F. Borrull, J. Martínez, A. Peñalver
article en

Abstract

Abstract The performance of TK100 resin was evaluated for the rapid and selective preconcentration of 226 Ra for environmental water matrices. High radium uptake was observed in 0.01 M HNO 3 and 0.01 M HCl, with weight distribution ratio above 1000 mL·g −1 , and > 95% retention achieved within 15 min. Adsorption decreased significantly at ≥ 0.1 M HNO 3 and 0.1 M HCl, with D w values decreasing from the order of 10 3 to 10 mL·g −1 . A similar decline was observed at high salinity, defining the operational matrix limits. Column tests confirmed that > 90% of 226 Ra was eluted with 10–15 mL of 0.1 M acid (HNO 3 , HCl). These findings demonstrate the suitability of TK100 for routine preconcentration of 226 Ra in routine environmental monitoring.

Journal of Radioanalytical and Nuclear Chemistry
Generalitat de Catalunya (ES), Universitat Rovira i Virgili (ES)
European Regional Development Fund, Agencia Estatal de Investigación
Clean water and sanitation
Openalex Percentile: Top 7%
Chemical Synthesis and Characterization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.