0241 Evaluation of Four Computational Methods to Estimate Dim Light Melatonin Onset in Pediatric Populations

Abstract Introduction Dim light melatonin onset (DLMO) is the gold standard circadian phase marker in humans. There are several methods that can be employed to estimate DLMO from salivary or plasma melatonin levels. These methods include utilizing fixed thresholds (3 pg/ml, 4 pg/ml), individual thresholds (2 SD above baseline), and the hockey stick method. The extant literature suggests that DLMO estimates in adults and adolescents are influenced by DLMO quantification methods. To date, no studies have compared these methods for calculating DLMO in pediatric populations. Given that measuring DLMO in children presents unique methodological challenges, research is needed to compare agreement across calculation methods. Methods Salivary melatonin was collected from 49 healthy children aged 3.3 – 6.0 years and retrospectively analyzed. Children maintained a consistent sleep/wake schedule for 7 days. On the evening of the 8th day, children provided saliva samples every 30 min until 1 h past habitual bedtime under dim light conditions (< 10 photopic lux). Saliva was collected by having each child mouth/chew on absorbent cotton swabs. DLMO was compared across four methods of calculation: 4 pg/ml fixed threshold, 3 pg/ml fixed threshold, individual thresholds calculated as 2 SD above baseline levels, and the hockey stick method. Results Intraclass correlations among the four methods were all significant (p < 0.001), with the strongest agreement observed between the 3 pg/ml, 4 pg/ml, and hockey stick methods. DLMO values from all methods were positively correlated with bedtime, sleep onset, midsleep, and sleep offset (p < 0.001). Although the 2 SD method was more discrepant from the other three estimation methods on average, it did yield a more plausible DLMO estimate in one individual identified as a high secretor. Conclusion The 3 pg/ml, 4 pg/ml, and hockey stick methods provide reliable estimates of DLMO in young children, whereas the 2 SD method may yield a more accurate DLMO estimation in edge cases of high or low melatonin secretors. More research is needed to generalize these overall findings to other pediatric populations, including those with known variability in melatonin output. Support (if any) Support for data collection came from F32-HD103390; R01-HD087707; T32-HL149646.

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0241
Primary Topic
Circadian rhythm and melatonin
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0241 Evaluation of Four Computational Methods to Estimate Dim Light Melatonin Onset in Pediatric Populations

Rebecca Cox, Lauren Hartstein, Isabella Sagman
SLEEP
Circadian rhythm and melatonin
article

0241 Evaluation of Four Computational Methods to Estimate Dim Light Melatonin Onset in Pediatric Populations

Rebecca Cox, Lauren Hartstein, Isabella Sagman
article en

Abstract

Abstract Introduction Dim light melatonin onset (DLMO) is the gold standard circadian phase marker in humans. There are several methods that can be employed to estimate DLMO from salivary or plasma melatonin levels. These methods include utilizing fixed thresholds (3 pg/ml, 4 pg/ml), individual thresholds (2 SD above baseline), and the hockey stick method. The extant literature suggests that DLMO estimates in adults and adolescents are influenced by DLMO quantification methods. To date, no studies have compared these methods for calculating DLMO in pediatric populations. Given that measuring DLMO in children presents unique methodological challenges, research is needed to compare agreement across calculation methods. Methods Salivary melatonin was collected from 49 healthy children aged 3.3 – 6.0 years and retrospectively analyzed. Children maintained a consistent sleep/wake schedule for 7 days. On the evening of the 8th day, children provided saliva samples every 30 min until 1 h past habitual bedtime under dim light conditions (< 10 photopic lux). Saliva was collected by having each child mouth/chew on absorbent cotton swabs. DLMO was compared across four methods of calculation: 4 pg/ml fixed threshold, 3 pg/ml fixed threshold, individual thresholds calculated as 2 SD above baseline levels, and the hockey stick method. Results Intraclass correlations among the four methods were all significant (p < 0.001), with the strongest agreement observed between the 3 pg/ml, 4 pg/ml, and hockey stick methods. DLMO values from all methods were positively correlated with bedtime, sleep onset, midsleep, and sleep offset (p < 0.001). Although the 2 SD method was more discrepant from the other three estimation methods on average, it did yield a more plausible DLMO estimate in one individual identified as a high secretor. Conclusion The 3 pg/ml, 4 pg/ml, and hockey stick methods provide reliable estimates of DLMO in young children, whereas the 2 SD method may yield a more accurate DLMO estimation in edge cases of high or low melatonin secretors. More research is needed to generalize these overall findings to other pediatric populations, including those with known variability in melatonin output. Support (if any) Support for data collection came from F32-HD103390; R01-HD087707; T32-HL149646.

SLEEPVol. 49(Supplement_1)
Vassar College (US), University of Arizona (US), Washington University in St. Louis (US)
Openalex Percentile: Top 8%
Circadian rhythm and melatonin
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.