Retentive Properties of Novaloc-TiN and Locator Overdenture Attachments: An In Vitro Physical and Thermal Analysis

PURPOSE: To compare the in-vitro retentive forces of Novaloc-TiN and Locator attachment systems for two-implant overdentures before and after insertion-removal and compressive cyclic loading, representing up to 12 months of wear. MATERIALS AND METHODS: Insertion-removal and compression-cycles of two-implant Novaloc (Novaloc® TiN, Straumann) and Locator (Locator®, Straumann) overdenture attachments embedded into 3D-printed acrylic blocks were performed (n=10 each). For compressive cycling, a force approximating 66.7-N was applied at the center of the blocks using a Bose ElectroForce Fatigue Testing machine over a sum of 300,000 cycles per sample. The retentive force was recorded at baseline and after certain insertion-removal (23, 270, 540, and 1080) and compression-cycles (5k, 25k, 75k, 150k, and 300k). Deformation and crystallization were assessed using micro-computed tomography and differential scanning calorimetry coupled with thermal gravimetric analysis. RESULTS: Compressive cycling of two-implant overdenture yielded a greater retentive force for Locator attachments relative to Novaloc-TiN attachments at simulated mastication equivalent to one-week, one, three, six and 12-months of wear. However, Locator attachments displayed fluctuating retentive forces throughout the 300,000-cycle duration. Retention forces for Novaloc system had no significant differences between baseline and the following 300,000 cycles, indicating consistent retention throughout the cycling duration. Similarly, insertion-removal cycles resulted in retention loss for Locator, whereas Novaloc showed more consistency. CONCLUSIONS: Novaloc-TiN system offers superior durability following compressive and insertion-removal cycling. This indicates more longevity for retentive forces relative to Locator attachment system, despite the lower overall retentive forces of Novaloc attachments.

Authors

Publication Details

Journal
The International Journal of Prosthodontics
Published
2026-05-01
DOI
https://doi.org/10.11607/ijp.9723
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retentive Properties of Novaloc-TiN and Locator Overdenture Attachments: An In Vitro Physical and Thermal Analysis

Dana Jafarpour, Nesma El-Amier, Eric Krochmalnek, Damiano Pasini et al.
The International Journal of Prosthodontics
Metal and Thin Film Mechanics
article

Retentive Properties of Novaloc-TiN and Locator Overdenture Attachments: An In Vitro Physical and Thermal Analysis

Dana Jafarpour, Nesma El-Amier, Eric Krochmalnek, Damiano Pasini, Raphael de Souza, Lei Wu
article en

Abstract

PURPOSE: To compare the in-vitro retentive forces of Novaloc-TiN and Locator attachment systems for two-implant overdentures before and after insertion-removal and compressive cyclic loading, representing up to 12 months of wear. MATERIALS AND METHODS: Insertion-removal and compression-cycles of two-implant Novaloc (Novaloc® TiN, Straumann) and Locator (Locator®, Straumann) overdenture attachments embedded into 3D-printed acrylic blocks were performed (n=10 each). For compressive cycling, a force approximating 66.7-N was applied at the center of the blocks using a Bose ElectroForce Fatigue Testing machine over a sum of 300,000 cycles per sample. The retentive force was recorded at baseline and after certain insertion-removal (23, 270, 540, and 1080) and compression-cycles (5k, 25k, 75k, 150k, and 300k). Deformation and crystallization were assessed using micro-computed tomography and differential scanning calorimetry coupled with thermal gravimetric analysis. RESULTS: Compressive cycling of two-implant overdenture yielded a greater retentive force for Locator attachments relative to Novaloc-TiN attachments at simulated mastication equivalent to one-week, one, three, six and 12-months of wear. However, Locator attachments displayed fluctuating retentive forces throughout the 300,000-cycle duration. Retention forces for Novaloc system had no significant differences between baseline and the following 300,000 cycles, indicating consistent retention throughout the cycling duration. Similarly, insertion-removal cycles resulted in retention loss for Locator, whereas Novaloc showed more consistency. CONCLUSIONS: Novaloc-TiN system offers superior durability following compressive and insertion-removal cycling. This indicates more longevity for retentive forces relative to Locator attachment system, despite the lower overall retentive forces of Novaloc attachments.

The International Journal of ProsthodonticsVol. 0(0)
Openalex Percentile: Top 8%
Metal and Thin Film Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.