1227 Validation of a Wrist-Worn Deep Learning Model for Sleep Staging Across the Spectrum of Sleep Apnea Severity

Abstract Introduction Advancements in wearable devices have made it possible to easily and noninvasively acquire biological signals over extended periods. However, when using wearable devices to evaluate sleep in individuals with or without sleep disorders, it is necessary to examine how overall device performance varies with the type and severity of the disorder. Methods We developed a deep learning model that uses RR intervals and acceleration data measured by a wrist-worn device as input and examined its performance in sleep stage classification. Simultaneous measurements were conducted using polysomnography (PSG) and the wrist-worn device on healthy individuals and patients with sleep apnea (SA), and PSG assessments by specialists were used as the reference standard. The evaluation included two groups—healthy individuals (50 nights) and patients with SA (50 nights)—with accuracy and Cohen’s kappa calculated for 5-stage classification, and the mean absolute error (MAE) for estimating total sleep time (TST). Furthermore, the SA group was divided into three subgroups based on AHI: (I) AHI< 30 (14 nights), (II) 30≤AHI< 50 (21 nights), and (III) AHI≥50 (15 nights), and each subgroup was evaluated separately. Results For the healthy group, the accuracy was 0.70, the kappa was 0.58, and the MAE was 14 min. For the SA group, the accuracy was 0.59, the kappa was 0.44, and the MAE was 26 min. Across the AHI-based subgroups, (I) showed 0.62/0.49/24 min, (II) 0.57/0.42/27 min, and (III) 0.60/0.42/29 min for the accuracy, kappa, and MAE, respectively. Conclusion Although performance in the SA group was slightly reduced compared with the healthy group, the MAE remained around 26 min (~10% of TST). In the AHI-based subgroups, (II) and (III) showed a modest reduction in accuracy and kappa compared with (I), while no marked difference was found between (II) and (III). The MAE for all subgroups stayed within 24–29 min, indicating limited influence of AHI. These findings suggest that even for patients with SA, regardless of severity (including very severe cases with AHI≥50), this method has practical potential as a convenient approach for sleep evaluations. Support (if any)

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.1226
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

1227 Validation of a Wrist-Worn Deep Learning Model for Sleep Staging Across the Spectrum of Sleep Apnea Severity

Yasuhiro Tomita, Syuhei FUJITA, Tomoko Yagi, Michiru Kaneda et al.
SLEEP
Obstructive Sleep Apnea Research
article

1227 Validation of a Wrist-Worn Deep Learning Model for Sleep Staging Across the Spectrum of Sleep Apnea Severity

Yasuhiro Tomita, Syuhei FUJITA, Tomoko Yagi, Michiru Kaneda, Sho Ogaki, Tomoyuki Nohara, Naoshi Osako, Takanori Ogata
article en

Abstract

Abstract Introduction Advancements in wearable devices have made it possible to easily and noninvasively acquire biological signals over extended periods. However, when using wearable devices to evaluate sleep in individuals with or without sleep disorders, it is necessary to examine how overall device performance varies with the type and severity of the disorder. Methods We developed a deep learning model that uses RR intervals and acceleration data measured by a wrist-worn device as input and examined its performance in sleep stage classification. Simultaneous measurements were conducted using polysomnography (PSG) and the wrist-worn device on healthy individuals and patients with sleep apnea (SA), and PSG assessments by specialists were used as the reference standard. The evaluation included two groups—healthy individuals (50 nights) and patients with SA (50 nights)—with accuracy and Cohen’s kappa calculated for 5-stage classification, and the mean absolute error (MAE) for estimating total sleep time (TST). Furthermore, the SA group was divided into three subgroups based on AHI: (I) AHI< 30 (14 nights), (II) 30≤AHI< 50 (21 nights), and (III) AHI≥50 (15 nights), and each subgroup was evaluated separately. Results For the healthy group, the accuracy was 0.70, the kappa was 0.58, and the MAE was 14 min. For the SA group, the accuracy was 0.59, the kappa was 0.44, and the MAE was 26 min. Across the AHI-based subgroups, (I) showed 0.62/0.49/24 min, (II) 0.57/0.42/27 min, and (III) 0.60/0.42/29 min for the accuracy, kappa, and MAE, respectively. Conclusion Although performance in the SA group was slightly reduced compared with the healthy group, the MAE remained around 26 min (~10% of TST). In the AHI-based subgroups, (II) and (III) showed a modest reduction in accuracy and kappa compared with (I), while no marked difference was found between (II) and (III). The MAE for all subgroups stayed within 24–29 min, indicating limited influence of AHI. These findings suggest that even for patients with SA, regardless of severity (including very severe cases with AHI≥50), this method has practical potential as a convenient approach for sleep evaluations. Support (if any)

SLEEPVol. 49(Supplement_1)
Kurume University (JP), Toranomon Hospital (JP), Aselsan (Turkey) (TR)
Quality Education
Openalex Percentile: Top 6%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.