0579 Feasibility of a Patch-Type Abdominal Sensor for Sleep Apnea and Hypopnea Detection: A Validation Study

Abstract Introduction Polysomnography (PSG) remains the standard for diagnosing sleep apnea but is limited by its high cost and in-lab setting. The ATP-T200 (ATsense, Korea) is a novel patch-type abdominal sensor that measures sleep respiration via capacitance changes reflecting distance between the patch electrode and the abdominal surface. This study evaluated its feasibility for detecting sleep respiratory events (apnea and hypopnea) compared with PSG recordings. Methods Adults (≥19 years) scheduled for PSG for clinical reasons were recruited.. The patch-type sensor was attached to the abdomen simultaneously with standard in-lab PSG. Abdominal signals were pre-processed and initially screened for event candidates using a rule-based algorithm, followed by refined detection with the Abdomen Abnormal Detection Net (AADNet), an AI model that learns local respiratory patterns and temporal dependencies for accurate event classification.Data were divided 1:1 into training and test sets for model development and evaluation. The accuracy of apnea–hypopnea index (AHI) estimation and epoch-by-epoch event detection were assessed, and the area under the receiver operating characteristic curve (AUROC) values were calculated using AHI thresholds of ≥15, and ≥30 events/h. Results After 8 were excluded due to poor signal quality, the final analysis included 88 participants (mean age 48.5 ± 15.5 years, 81% men, BMI 26.0 ± 4.2 kg/m2). Participants were randomly divided into training (n = 44) and test (n = 44) sets, stratified by sex, age, and BMI without significant group differences. For the AHI, strong correlation was observed between the patch-based and PSG measurements (Pearson r = 0.902, p < 0.001), and Bland–Altman analysis showed a mean difference of 0.82. When classifying patients by AHI thresholds, AUROC values were 0.963 for both AHI ≥ 15 (29/44; sensitivity 89.2%, specificity 85.7%) and AHI ≥ 30 (15/44; sensitivity 93.3%, specificity 93.1%). Epoch-by-epoch analysis demonstrated sensitivity 83.3%, specificity 91.6%, accuracy 89.5%, and F1-score 80.0. Conclusion The patch-type abdominal sensor showed strong agreement with PSG and accurately estimating AHI across clinically relevant thresholds. These findings support the feasibility of abdominal capacitance–based respiration monitoring combined with AI-driven event detection as a practical approach for screening and follow-up outside the sleep laboratory. Support (if any) This study was supported by ATsense, Korea.

Authors

Institutions

Publication Details

Journal
SLEEP
Published
2026-05-01
DOI
https://doi.org/10.1093/sleep/zsag091.0578
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

0579 Feasibility of a Patch-Type Abdominal Sensor for Sleep Apnea and Hypopnea Detection: A Validation Study

Jeong‐Whun Kim, Jung Kyung Hong, In-Young Yoon, Minji Lee
SLEEP
Obstructive Sleep Apnea Research
article

0579 Feasibility of a Patch-Type Abdominal Sensor for Sleep Apnea and Hypopnea Detection: A Validation Study

Jeong‐Whun Kim, Jung Kyung Hong, In-Young Yoon, Minji Lee
article en

Abstract

Abstract Introduction Polysomnography (PSG) remains the standard for diagnosing sleep apnea but is limited by its high cost and in-lab setting. The ATP-T200 (ATsense, Korea) is a novel patch-type abdominal sensor that measures sleep respiration via capacitance changes reflecting distance between the patch electrode and the abdominal surface. This study evaluated its feasibility for detecting sleep respiratory events (apnea and hypopnea) compared with PSG recordings. Methods Adults (≥19 years) scheduled for PSG for clinical reasons were recruited.. The patch-type sensor was attached to the abdomen simultaneously with standard in-lab PSG. Abdominal signals were pre-processed and initially screened for event candidates using a rule-based algorithm, followed by refined detection with the Abdomen Abnormal Detection Net (AADNet), an AI model that learns local respiratory patterns and temporal dependencies for accurate event classification.Data were divided 1:1 into training and test sets for model development and evaluation. The accuracy of apnea–hypopnea index (AHI) estimation and epoch-by-epoch event detection were assessed, and the area under the receiver operating characteristic curve (AUROC) values were calculated using AHI thresholds of ≥15, and ≥30 events/h. Results After 8 were excluded due to poor signal quality, the final analysis included 88 participants (mean age 48.5 ± 15.5 years, 81% men, BMI 26.0 ± 4.2 kg/m2). Participants were randomly divided into training (n = 44) and test (n = 44) sets, stratified by sex, age, and BMI without significant group differences. For the AHI, strong correlation was observed between the patch-based and PSG measurements (Pearson r = 0.902, p < 0.001), and Bland–Altman analysis showed a mean difference of 0.82. When classifying patients by AHI thresholds, AUROC values were 0.963 for both AHI ≥ 15 (29/44; sensitivity 89.2%, specificity 85.7%) and AHI ≥ 30 (15/44; sensitivity 93.3%, specificity 93.1%). Epoch-by-epoch analysis demonstrated sensitivity 83.3%, specificity 91.6%, accuracy 89.5%, and F1-score 80.0. Conclusion The patch-type abdominal sensor showed strong agreement with PSG and accurately estimating AHI across clinically relevant thresholds. These findings support the feasibility of abdominal capacitance–based respiration monitoring combined with AI-driven event detection as a practical approach for screening and follow-up outside the sleep laboratory. Support (if any) This study was supported by ATsense, Korea.

SLEEPVol. 49(Supplement_1)
Soonchunhyang University Hospital Seoul (KR), Seoul National University Bundang Hospital (KR)
Openalex Percentile: Top 7%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.