ML‐Assisted Accuracy Prediction of a Silicon Carbide–Based SPR Biosensor for Acetone Concentration Measurement

ABSTRACT An enhanced surface plasmon resonance biosensor is designed for acetone concentration measurement in exhaled breath (EB) and exhaled breath condensate (EBC) using the Kretschmann configuration and the Fresnel multilayer concept. After analyzing different plasmonic metals and substrate materials, it is concluded that for realizing deeper resonance and greater angular sensitivities, for acetone measurement in EB and EBC, a CsF prism is more optimal as a substrate material. Black phosphorus is employed in this design for its potential to act as a selective layer through chemisorption, which fully relies on its extremely active two‐dimensional surface and dipole interaction effect to boost permittivity variation at the metal–dielectric interface. Finally, simulation design is ensured to be accurate through simulation using various methods: optimization of sensor design through the use of Transfer Matrix Method (TMM) and Finite Element Method (FEM), and verification of resonance and electrical field simulation through Finite Difference Time Domain (FDTD) simulation. The designed optimized structure reveals a high sensitivity of 332.53 deg/RIU, a figure of merit of 115.78, a quality factor of 126.47 RIU −1 , and a minimum reflection of 0.0002. In addition, the validity of the accuracy of Artificial Neural Network (ANN) and Adaptive Neuro‐Fuzzy Inference System (ANFIS) models in describing the simulation of sensor response has been verified for a dependable precise measurement of acetone concentration. This designed SPR biosensor unveils a vast improvement over existing designs with immense potential for utilization in noninvasive acetone breath analysis.

Authors

Institutions

Publication Details

Journal
Journal of the American Ceramic Society
Published
2026-05-01
DOI
https://doi.org/10.1111/jace.70818
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ML‐Assisted Accuracy Prediction of a Silicon Carbide–Based SPR Biosensor for Acetone Concentration Measurement

Khandakar Mohammad Ishtiak, Maymona Binte Juwel, Md. Tajrian Bhuiyan, Md. Al Amin Islam Utshob et al.
Journal of the American Ceramic Society
Advanced Chemical Sensor Technologies
article

ML‐Assisted Accuracy Prediction of a Silicon Carbide–Based SPR Biosensor for Acetone Concentration Measurement

Khandakar Mohammad Ishtiak, Maymona Binte Juwel, Md. Tajrian Bhuiyan, Md. Al Amin Islam Utshob, Safayat‐Al Imam, M. M. Atiqur Rahman
article en

Abstract

ABSTRACT An enhanced surface plasmon resonance biosensor is designed for acetone concentration measurement in exhaled breath (EB) and exhaled breath condensate (EBC) using the Kretschmann configuration and the Fresnel multilayer concept. After analyzing different plasmonic metals and substrate materials, it is concluded that for realizing deeper resonance and greater angular sensitivities, for acetone measurement in EB and EBC, a CsF prism is more optimal as a substrate material. Black phosphorus is employed in this design for its potential to act as a selective layer through chemisorption, which fully relies on its extremely active two‐dimensional surface and dipole interaction effect to boost permittivity variation at the metal–dielectric interface. Finally, simulation design is ensured to be accurate through simulation using various methods: optimization of sensor design through the use of Transfer Matrix Method (TMM) and Finite Element Method (FEM), and verification of resonance and electrical field simulation through Finite Difference Time Domain (FDTD) simulation. The designed optimized structure reveals a high sensitivity of 332.53 deg/RIU, a figure of merit of 115.78, a quality factor of 126.47 RIU −1 , and a minimum reflection of 0.0002. In addition, the validity of the accuracy of Artificial Neural Network (ANN) and Adaptive Neuro‐Fuzzy Inference System (ANFIS) models in describing the simulation of sensor response has been verified for a dependable precise measurement of acetone concentration. This designed SPR biosensor unveils a vast improvement over existing designs with immense potential for utilization in noninvasive acetone breath analysis.

Journal of the American Ceramic SocietyVol. 109(5)
Ahsanullah University of Science and Technology (BD)
Openalex Percentile: Top 8%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.