Comparative analysis of serological reactivity in genetically confirmed <scp>Rh</scp> variants within a recipient population

BACKGROUND AND OBJECTIVES: Detecting Rh variants in transfusion recipients is essential to prevent alloimmunization. This study compared the serological reactivity of various monoclonal antibodies using two techniques (gel column agglutination and microplate technology at room temperature) in relation to genetically confirmed Rh variants. MATERIALS AND METHODS: Over an 18-month period, all EDTA blood samples referred to the molecular laboratory were analysed. RHD and RHCE genotyping was performed, and samples carrying at least one variant allele underwent serological testing. Statistical analysis was performed using the McNemar test (p < 0.05). RESULTS: Among 610 samples, 118 (19%) carried at least one Rh variant. The most frequent alleles were RHCE*CeRN (n = 39) and RHD*weak D type 1 (n = 14). Weak RhD (types 1 and 3) and partial RhD from RHD*DAR were serologically weakened (<4+) with both methods. Homozygosity for RHCE*CeRN was suggested by serological weakening of RH5 with both methods, whereas heterozygosity was indicated by serological weakening of RH2 with microplate only. Other variants with a few samples (RH1 of RHD*weak D type 2 and 5, RH2 of RHD*RHD-CE (4-7)-D, RH3 of RHCE*cEIV, RH4 of RHCE*ceJAL and RH5 of RHCE*ceMO.01 and RHCE*ceAR) showed weak serological intensities but lacked statistical confirmation. Finally, 39% of Rh variants were not detected as serologically weakened by both serological methods. CONCLUSION: Phenotyping remains the first-line screening tool. Weak serological intensities help guide molecular investigations. However, detection of Rh variants using serology alone is highly variable. Combining different clones and techniques improves sensitivity.

Authors

Institutions

Publication Details

Journal
Vox Sanguinis
Published
2026-05-08
DOI
https://doi.org/10.1111/vox.70285
Primary Topic
Blood groups and transfusion
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative analysis of serological reactivity in genetically confirmed Rh variants within a recipient population

Maïlis Lauwers, Hanane El Kenz, Saad Bakrim, Philippe Akiki et al.
Vox Sanguinis
Blood groups and transfusion
article

Comparative analysis of serological reactivity in genetically confirmed Rh variants within a recipient population

Maïlis Lauwers, Hanane El Kenz, Saad Bakrim, Philippe Akiki, Mélanie Monfort, Samy Bensaid
article en

Abstract

BACKGROUND AND OBJECTIVES: Detecting Rh variants in transfusion recipients is essential to prevent alloimmunization. This study compared the serological reactivity of various monoclonal antibodies using two techniques (gel column agglutination and microplate technology at room temperature) in relation to genetically confirmed Rh variants. MATERIALS AND METHODS: Over an 18-month period, all EDTA blood samples referred to the molecular laboratory were analysed. RHD and RHCE genotyping was performed, and samples carrying at least one variant allele underwent serological testing. Statistical analysis was performed using the McNemar test (p < 0.05). RESULTS: Among 610 samples, 118 (19%) carried at least one Rh variant. The most frequent alleles were RHCE*CeRN (n = 39) and RHD*weak D type 1 (n = 14). Weak RhD (types 1 and 3) and partial RhD from RHD*DAR were serologically weakened (<4+) with both methods. Homozygosity for RHCE*CeRN was suggested by serological weakening of RH5 with both methods, whereas heterozygosity was indicated by serological weakening of RH2 with microplate only. Other variants with a few samples (RH1 of RHD*weak D type 2 and 5, RH2 of RHD*RHD-CE (4-7)-D, RH3 of RHCE*cEIV, RH4 of RHCE*ceJAL and RH5 of RHCE*ceMO.01 and RHCE*ceAR) showed weak serological intensities but lacked statistical confirmation. Finally, 39% of Rh variants were not detected as serologically weakened by both serological methods. CONCLUSION: Phenotyping remains the first-line screening tool. Weak serological intensities help guide molecular investigations. However, detection of Rh variants using serology alone is highly variable. Combining different clones and techniques improves sensitivity.

Vox Sanguinis
Université Libre de Bruxelles (BE), Université Ibn Zohr (MA), Centre Hospitalier Universitaire Brugmann (BE), National Bank of Belgium (BE)
Openalex Percentile: Top 5%
Blood groups and transfusion
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.