Feasibility Analysis of Geothermal Energy Utilization in Ultra-Low Temperature District Heating Networks: Effect of Heat Distribution in Underground Tunnels

The integration of ground-source heat pumps into ultra-low-temperature district heating networks represents a promising pathway for decarbonizing urban heat supply and mitigating the shortcomings of conventional high-temperature district heating systems. However, the feasibility of such systems depends on several technical factors related to operating conditions, demand characteristics and heat distribution. This study evaluates the technical feasibility and annual performance of a geothermal heat pump–based ultra-low temperature district heating system operating at supply and return temperatures of 35/20 °C under realistic boundary conditions. The investigated system consists of a ground-source heat pump connected to a borehole field comprising 135 boreholes, each 200 m deep, serving a district heating network with a peak demand of 5.2 MW. A system-level modelling framework implemented in MATLAB/Simulink is used, with district-heating boundary conditions derived from Leanheat® network simulations, to assess a partial peak-load coverage strategy, geothermal borefield behaviour, and the influence of network temperature level and distribution environment, including tunnel based pipe routing, on system performance. The results show that a heat pump sized to cover a fraction of the peak demand can supply approximately 69% of the annual heat demand while achieving a seasonal performance factor of 3.82. Borefield operation remains thermally feasible throughout the annual cycle, with no freezing observed at the borehole outlet. A comparative analysis shows that increasing the network temperature level to 60/40 °C results in similar demand coverage but significantly higher electricity consumption due to reduced heat pump efficiency. Furthermore, routing district heating pipes through an underground tunnel environment reduces annual distribution heat losses by approximately 183 MWh without significantly affecting heat pump performance or hydraulic behaviour. A sensitivity check shows that the tunnel environment partially offsets the increase in distribution heat losses associated with reduced pipe insulation. • Feasibility of GSHP integration in ULTDH assessed using realistic operating data • Partial peak-load GSHP supplies 69% of annual heat with SPF of 3.82 • Borefield operates stably with no freezing under ULTDH conditions • Tunnel-based pipe routing reduces distribution losses by ∼183 MWh annually • Network temperature level strongly influences GSHP efficiency and electricity use

Authors

Institutions

Publication Details

Journal
Renewable Energy
Published
2026-05-01
DOI
https://doi.org/10.1016/j.renene.2026.125920
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility Analysis of Geothermal Energy Utilization in Ultra-Low Temperature District Heating Networks: Effect of Heat Distribution in Underground Tunnels

Aleksandr Ledvanov, Igor Krupenski, Mohammad Sameti, Sylvester Ofili et al.
Renewable Energy
Geothermal Energy Systems and Applications
article

Feasibility Analysis of Geothermal Energy Utilization in Ultra-Low Temperature District Heating Networks: Effect of Heat Distribution in Underground Tunnels

Aleksandr Ledvanov, Igor Krupenski, Mohammad Sameti, Sylvester Ofili, Kertu Lepiksar, Hossein Alimohammadi, Anna Volkova, Sreenath Sukumaran, Zili Li
article en

Abstract

The integration of ground-source heat pumps into ultra-low-temperature district heating networks represents a promising pathway for decarbonizing urban heat supply and mitigating the shortcomings of conventional high-temperature district heating systems. However, the feasibility of such systems depends on several technical factors related to operating conditions, demand characteristics and heat distribution. This study evaluates the technical feasibility and annual performance of a geothermal heat pump–based ultra-low temperature district heating system operating at supply and return temperatures of 35/20 °C under realistic boundary conditions. The investigated system consists of a ground-source heat pump connected to a borehole field comprising 135 boreholes, each 200 m deep, serving a district heating network with a peak demand of 5.2 MW. A system-level modelling framework implemented in MATLAB/Simulink is used, with district-heating boundary conditions derived from Leanheat® network simulations, to assess a partial peak-load coverage strategy, geothermal borefield behaviour, and the influence of network temperature level and distribution environment, including tunnel based pipe routing, on system performance. The results show that a heat pump sized to cover a fraction of the peak demand can supply approximately 69% of the annual heat demand while achieving a seasonal performance factor of 3.82. Borefield operation remains thermally feasible throughout the annual cycle, with no freezing observed at the borehole outlet. A comparative analysis shows that increasing the network temperature level to 60/40 °C results in similar demand coverage but significantly higher electricity consumption due to reduced heat pump efficiency. Furthermore, routing district heating pipes through an underground tunnel environment reduces annual distribution heat losses by approximately 183 MWh without significantly affecting heat pump performance or hydraulic behaviour. A sensitivity check shows that the tunnel environment partially offsets the increase in distribution heat losses associated with reduced pipe insulation. • Feasibility of GSHP integration in ULTDH assessed using realistic operating data • Partial peak-load GSHP supplies 69% of annual heat with SPF of 3.82 • Borefield operates stably with no freezing under ULTDH conditions • Tunnel-based pipe routing reduces distribution losses by ∼183 MWh annually • Network temperature level strongly influences GSHP efficiency and electricity use

Renewable Energy
Tallinn University of Technology (EE), University College Cork (IE), Estonian Association for Applied Linguistics (EE)
Eesti Teadusagentuur, Geological Survey of Ireland
Affordable and clean energy
Openalex Percentile: Top 16%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.