Effect of three-segment scanning on the accuracy of intraoral scans in full-arch implant-supported rehabilitation: an in vitro study

PURPOSE: To evaluate the effect of three-segment scanning on the accuracy of digital impressions of full-arch implants obtained using intraoral scanners. METHODS: An edentulous master model with six implants was digitized using a laboratory scanner to create a reference scan. Three intraoral scanners (Primescan, Aoralscan 3 and Trios 5) and two scan strategies were evaluated (n = 10): full-scan (simultaneous full-arch scan) and segmented-scan (the arch categorized into three segments, scanned independently, and subsequently composed into a full-arch dataset) groups. The reference data were scanned using a laboratory scanner. Surface deviation was evaluated with a tolerance of ± 50 μm. The percentage of the total scan body surface area within this tolerance range was calculated as surface trueness. The overall distance deviation between scan bodies was measured to determine linear trueness and precision. RESULTS: For Aoralscan 3 and Trios 5, the segmented-scan group showed higher surface trueness than the full-arch scan group, whereas Primescan showed no statistically significant difference between the scan strategies. The overall distance deviation showed no significant differences in trueness between the full-arch and segmented scans for Primescan, Aoralscan 3, or Trios 5 (all p > 0.05). However, precision was significantly higher under the segmented-scan condition than with full-arch scanning for all evaluated intraoral scanners (all p < 0.01). CONCLUSIONS: For full-arch implant impressions using intraoral scanners, segmented scanning with subsequent composition into a full-arch digital model improved intraoral scanning accuracy compared with simultaneous full-arch scanning.

Authors

Institutions

Publication Details

Journal
International Journal of Implant Dentistry
Published
2026-05-08
DOI
https://doi.org/10.1186/s40729-026-00692-4
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of three-segment scanning on the accuracy of intraoral scans in full-arch implant-supported rehabilitation: an in vitro study

Yusuke Uto, Tetsurou Odatsu, Yuki Sato, Takashi Sawase et al.
International Journal of Implant Dentistry
Dental Implant Techniques and Outcomes
article

Effect of three-segment scanning on the accuracy of intraoral scans in full-arch implant-supported rehabilitation: an in vitro study

Yusuke Uto, Tetsurou Odatsu, Yuki Sato, Takashi Sawase, Masami Arai
article en

Abstract

PURPOSE: To evaluate the effect of three-segment scanning on the accuracy of digital impressions of full-arch implants obtained using intraoral scanners. METHODS: An edentulous master model with six implants was digitized using a laboratory scanner to create a reference scan. Three intraoral scanners (Primescan, Aoralscan 3 and Trios 5) and two scan strategies were evaluated (n = 10): full-scan (simultaneous full-arch scan) and segmented-scan (the arch categorized into three segments, scanned independently, and subsequently composed into a full-arch dataset) groups. The reference data were scanned using a laboratory scanner. Surface deviation was evaluated with a tolerance of ± 50 μm. The percentage of the total scan body surface area within this tolerance range was calculated as surface trueness. The overall distance deviation between scan bodies was measured to determine linear trueness and precision. RESULTS: For Aoralscan 3 and Trios 5, the segmented-scan group showed higher surface trueness than the full-arch scan group, whereas Primescan showed no statistically significant difference between the scan strategies. The overall distance deviation showed no significant differences in trueness between the full-arch and segmented scans for Primescan, Aoralscan 3, or Trios 5 (all p > 0.05). However, precision was significantly higher under the segmented-scan condition than with full-arch scanning for all evaluated intraoral scanners (all p < 0.01). CONCLUSIONS: For full-arch implant impressions using intraoral scanners, segmented scanning with subsequent composition into a full-arch digital model improved intraoral scanning accuracy compared with simultaneous full-arch scanning.

International Journal of Implant Dentistry
Kohno Clinical Medicine Research Institute (JP), Nagasaki University (JP), Yokohama City University (JP)
Openalex Percentile: Top 4%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.