A Study on the Determination of Time Domain Based on Governor-Free Response Qualification in the Korean Power System

in low-inertia power systems. In the Korean power system, Governor-Free (GF) performance is conventionally assessed using a fixed evaluation framework with a 10 s grace period and a 50 s assessment window after a frequency event. However, this approach does not adequately reflect generator-specific dynamic characteristics and may include the effects of Automatic Generation Control (AGC) in the GF assessment result.<br/>This paper proposes a generator-specific GF-only evaluation window based on the dynamic characteristics of the GGOV1 governor model. By considering actuator delay, fuel system dynamics, and turbine response, the effective GF response interval was derived as 2.3–7 s for the target generator. Case studies using actual system event data show that the conventional fixed window can distort the actual GF contribution of individual generators, whereas the proposed method more clearly captures the initial primary frequency response while reducing AGC influence. The proposed approach can improve the fairness and physical consistency of GF performance assessment in low-inertia power systems.

Authors

Publication Details

Journal
The Transactions of The Korean Institute of Electrical Engineers
Published
2026-05-08
DOI
https://doi.org/10.5370/kiee.2026.75.5.1017
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Determination of Time Domain Based on Governor-Free Response Qualification in the Korean Power System

Sangwook Han, Jonghoon Lee, Dabin Son
The Transactions of The Korean Institute of Electrical Engineers
Frequency Control in Power Systems
article

A Study on the Determination of Time Domain Based on Governor-Free Response Qualification in the Korean Power System

Sangwook Han, Jonghoon Lee, Dabin Son
article en

Abstract

in low-inertia power systems. In the Korean power system, Governor-Free (GF) performance is conventionally assessed using a fixed evaluation framework with a 10 s grace period and a 50 s assessment window after a frequency event. However, this approach does not adequately reflect generator-specific dynamic characteristics and may include the effects of Automatic Generation Control (AGC) in the GF assessment result.<br/>This paper proposes a generator-specific GF-only evaluation window based on the dynamic characteristics of the GGOV1 governor model. By considering actuator delay, fuel system dynamics, and turbine response, the effective GF response interval was derived as 2.3–7 s for the target generator. Case studies using actual system event data show that the conventional fixed window can distort the actual GF contribution of individual generators, whereas the proposed method more clearly captures the initial primary frequency response while reducing AGC influence. The proposed approach can improve the fairness and physical consistency of GF performance assessment in low-inertia power systems.

The Transactions of The Korean Institute of Electrical EngineersVol. 75(5)
Affordable and clean energy
Openalex Percentile: Top 8%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.