K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study

Retention of metal implants after Scarf–Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). Both groups showed significant clinical and radiographic improvement (P < 0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P > 0.05). Treatment costs were significantly lower in the K-wire group (P < 0.001). K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. Level of evidence Level III

Authors

Institutions

Publication Details

Journal
Foot and Ankle Surgery
Published
2026-05-01
DOI
https://doi.org/10.1016/j.fas.2026.05.001
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study

Mohamed Lamin Bangura, Yongli Jin, Boming Zhao, Awan Nasir Ikram et al.
Foot and Ankle Surgery
Foot and Ankle Surgery
article

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study

Mohamed Lamin Bangura, Yongli Jin, Boming Zhao, Awan Nasir Ikram, Chao Meng, Yutian Qiu, Manhua Huang
article en

Abstract

Retention of metal implants after Scarf–Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). Both groups showed significant clinical and radiographic improvement (P < 0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P > 0.05). Treatment costs were significantly lower in the K-wire group (P < 0.001). K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. Level of evidence Level III

Foot and Ankle Surgery
Yangtze University (CN), First People's Hospital of Jingzhou (CN)
Openalex Percentile: Top 6%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.