Research progress on end-tidal carbon dioxide detection technology

End-tidal carbon dioxide (ETCO<sub>2</sub>), as an important physiological parameter reflecting the state of gas exchange in the lungs, has significant application value in medical scenarios such as respiratory disease management. With the increasing demand for respiratory health monitoring and portable medical devices, respiratory monitoring is advancing toward continuous, non-invasive, and portable approaches. ETCO<sub>2</sub> detection technology faces multiple engineering constraints, including dynamic response, high humidity interference, and system miniaturization, which impose stringent requirements on the overall performance of sensing technologies. This paper, starting from the application scenarios of ETCO<sub>2</sub> detection, systematically analyzes its key technical constraints in terms of concentration range, dynamic characteristics, environmental interference, and engineering implementation. Based on this analysis, a comparative evaluation is conducted of CO<sub>2</sub> gas sensing technologies, including non-dispersive infrared (NDIR), photoacoustic spectroscopy (PAS), tunable diode laser absorption spectroscopy (TDLAS), solid-state gas sensing, and semiconductor sensing<sub>2</sub>. Through comprehensive multi-parameter analysis, NDIR technology demonstrates optimal overall suitability for ETCO<sub>2</sub> detection requirements in terms of selectivity, measurement range, system complexity, and engineering feasibility. Furthermore, this paper reviews the research progress of NDIR technology in ETCO<sub>2</sub> detection and concludes that future advancements in ETCO<sub>2</sub> detection can achieve continuous improvements in high precision, low power consumption, and multi-parameter fusion within NDIR-based systems through device optimization, system integration, and data-driven approaches, thereby providing critical technical support for continuous monitoring and accurate assessment of respiratory health.

Authors

Publication Details

Journal
Gongneng cailiao yu qijian xuebao
Published
2026-05-01
DOI
https://doi.org/10.3724/jfmd.2603043
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research progress on end-tidal carbon dioxide detection technology

Yanxiang Liu, Zhuoqing Yang, Wei Xiang Wang, Tie LI et al.
Gongneng cailiao yu qijian xuebao
Spectroscopy and Laser Applications
article

Research progress on end-tidal carbon dioxide detection technology

Yanxiang Liu, Zhuoqing Yang, Wei Xiang Wang, Tie LI, Yi Wang
article en

Abstract

End-tidal carbon dioxide (ETCO<sub>2</sub>), as an important physiological parameter reflecting the state of gas exchange in the lungs, has significant application value in medical scenarios such as respiratory disease management. With the increasing demand for respiratory health monitoring and portable medical devices, respiratory monitoring is advancing toward continuous, non-invasive, and portable approaches. ETCO<sub>2</sub> detection technology faces multiple engineering constraints, including dynamic response, high humidity interference, and system miniaturization, which impose stringent requirements on the overall performance of sensing technologies. This paper, starting from the application scenarios of ETCO<sub>2</sub> detection, systematically analyzes its key technical constraints in terms of concentration range, dynamic characteristics, environmental interference, and engineering implementation. Based on this analysis, a comparative evaluation is conducted of CO<sub>2</sub> gas sensing technologies, including non-dispersive infrared (NDIR), photoacoustic spectroscopy (PAS), tunable diode laser absorption spectroscopy (TDLAS), solid-state gas sensing, and semiconductor sensing<sub>2</sub>. Through comprehensive multi-parameter analysis, NDIR technology demonstrates optimal overall suitability for ETCO<sub>2</sub> detection requirements in terms of selectivity, measurement range, system complexity, and engineering feasibility. Furthermore, this paper reviews the research progress of NDIR technology in ETCO<sub>2</sub> detection and concludes that future advancements in ETCO<sub>2</sub> detection can achieve continuous improvements in high precision, low power consumption, and multi-parameter fusion within NDIR-based systems through device optimization, system integration, and data-driven approaches, thereby providing critical technical support for continuous monitoring and accurate assessment of respiratory health.

Gongneng cailiao yu qijian xuebao
Openalex Percentile: Top 10%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research progress on end-tidal carbon dioxide detection technology — Yanxiang Liu, Zhuoqing Yang, et al. · Gongneng cailiao yu qijian xuebao (2026) | TGRS Research Map | TGRS