Evaluation of apap parameters in one to three nights titration for final pressure decision-making in a real world clinical setting

PURPOSE: Compare pressure values obtained from APAP titration with the final pressure (PF) selected by the clinician to approximate and optimize as much as possible our OSA patients treatment management. METHODS: Retrospective descriptive study in 114 OSA treated patients. After 2-3 months with empiric CPAP pressure, they underwent 2-3 nights with 2 different APAP devices to help clinicians to decide an APAP pressure according to percentile 95 (P95) and median (Pm) values after visual analysis. We selected 60 patients (30 for each device) meeting the inclusion criteria until our 3 months follow-up consultation when, according to clinical outcomes, final pressure (PF) is established. Data analysis was blind and random, by an experienced and independent sleep physician and how and why the clinicians used the APAP was statistically evaluated, measuring parameters from each device for every patient and combination of nights and comparing them with PF, whose correlation with AHI was also analyzed. RESULTS: We found only significant evidence (p < 0.05) using Pm and Resmed device and considering AHI as a compliance predictive value, but no statistical difference (p > 0.05) performing more than one APAP night. CONCLUSIONS: A single night of APAP titration and use of the median pressure may suffice to determine an optimal fixed CPAP setting in our patients. We discuss limitations including small sample size, exclusion of unstable patients and absence of laboratory PSG comparison and Spanish-specific practice patterns.

Authors

Institutions

Publication Details

Journal
Sleep And Breathing
Published
2026-05-01
DOI
https://doi.org/10.1007/s11325-025-03481-2
Primary Topic
Obstructive Sleep Apnea Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of apap parameters in one to three nights titration for final pressure decision-making in a real world clinical setting

Estefanía Estévez, Jorge Pinel, Marta Palop, Jesús Escribá-Alepuz et al.
Sleep And Breathing
Obstructive Sleep Apnea Research
article

Evaluation of apap parameters in one to three nights titration for final pressure decision-making in a real world clinical setting

Estefanía Estévez, Jorge Pinel, Marta Palop, Jesús Escribá-Alepuz, Alberto Saura, Amparo Lloris, Lidia Herrero, F. Javier Puertas, Gemma Ramos, Oldar Cercas, José Segrelles
article en

Abstract

PURPOSE: Compare pressure values obtained from APAP titration with the final pressure (PF) selected by the clinician to approximate and optimize as much as possible our OSA patients treatment management. METHODS: Retrospective descriptive study in 114 OSA treated patients. After 2-3 months with empiric CPAP pressure, they underwent 2-3 nights with 2 different APAP devices to help clinicians to decide an APAP pressure according to percentile 95 (P95) and median (Pm) values after visual analysis. We selected 60 patients (30 for each device) meeting the inclusion criteria until our 3 months follow-up consultation when, according to clinical outcomes, final pressure (PF) is established. Data analysis was blind and random, by an experienced and independent sleep physician and how and why the clinicians used the APAP was statistically evaluated, measuring parameters from each device for every patient and combination of nights and comparing them with PF, whose correlation with AHI was also analyzed. RESULTS: We found only significant evidence (p < 0.05) using Pm and Resmed device and considering AHI as a compliance predictive value, but no statistical difference (p > 0.05) performing more than one APAP night. CONCLUSIONS: A single night of APAP titration and use of the median pressure may suffice to determine an optimal fixed CPAP setting in our patients. We discuss limitations including small sample size, exclusion of unstable patients and absence of laboratory PSG comparison and Spanish-specific practice patterns.

Sleep And BreathingVol. 30(2)
Universitat de Miguel Hernández d'Elx (ES), Air Liquide (United Kingdom) (GB), Instituto de Salud Carlos III (ES), Sleep Research Society (US), Valencia Catholic University Saint Vincent Martyr (ES), Fundación para el Fomento de la Investigación Sanitaria y Biomédica de la Comunitat Valenciana (ES), Hospital de Sagunto (ES), Air Liquide (United States) (US)
Universidad Miguel Hernández
Peace, Justice and strong institutions
Openalex Percentile: Top 9%
Obstructive Sleep Apnea Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.