Improving Bone Mineral Density Assessment in Total Shoulder Arthroplasty: Assessment of Phantom-Calibrated Hounsfield Units in the Glenoid and Proximal Humerus

Background: Bone mineral density (BMD) plays a critical role in the success of total shoulder arthroplasty (TSA), as poor bone quality is associated with poor implant fixation, particularly in short stem and stemless designs that rely on metaphyseal fixation.However, Dual-Energy X-ray Absorptiometry (DEXA) scans are not routinely obtained preoperatively.Computed tomography (CT)-derived Hounsfield units (HU) have emerged as a potential surrogate for BMD assessment, but HU values can have high variability, which limits accuracy.Phantom calibration (PC) may standardize HU values, but its benefit in the shoulder remains unclear.This study aimed to compare correlations of standard and PC-HU with DEXA-derived BMD, assess their diagnostic performance with receiver operating characteristic (ROC) analysis, and identify HU thresholds for osteoporosis detection. Materials & Methods:A retrospective analysis was performed on 84 shoulders from 76 patients, with some patients contributing bilateral shoulders.All patients underwent both shoulder CT and DEXA within one year of a TSA.Demographics, clinical information, and behavioral factors were collected.HU values were measured from the glenoid and proximal humerus and were calibrated to mg/cc using a phantom.Correlations between HU and DEXA Tscores in the femoral neck, total hip, and spine were evaluated using Spearman's correlation.ROC curve analysis was used to identify optimal HU thresholds for osteoporosis classification. J o u r n a l P r e -p r o o fResults: Both standard and PC HU (mg/cc) values of the glenoid and proximal humerus significantly correlated with DEXA T-scores (p < 0.001), though standard HU generally demonstrated stronger correlations.Optimal thresholds for identifying osteoporosis were 185.38 for the non-PC glenoid (sensitivity = 83.3%,specificity = 65.7%) and 30.90 for the proximal humerus (sensitivity = 78.6%,specificity = 75%).The PC glenoid threshold of 236.44 yielded slightly higher sensitivity (90.9%) but lower specificity (59.0%).PC proximal humerus HU did not demonstrate significant discriminatory power. Conclusion:The optimal thresholds for identifying osteoporosis were 185.38 HU for the non-PC glenoid, 30.90 HU for the non-PC proximal humerus, and 236.44 mg/cc for the PC glenoid.Both standard and PC HU values of the glenoid and proximal humerus significantly correlated with DEXA T-scores, although standard HU generally showed stronger correlations.These findings suggest that phantom-based calibration at these sites may offer no additional benefit in assessing systemic BMD.

Authors

Institutions

Publication Details

Journal
JSES International
Published
2026-05-01
DOI
https://doi.org/10.1016/j.jseint.2026.101730
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Bone Mineral Density Assessment in Total Shoulder Arthroplasty: Assessment of Phantom-Calibrated Hounsfield Units in the Glenoid and Proximal Humerus

Saagar Dhanjani, Darryl D. DʼLima, Heinz R. Hoenecke, Clarence Cabatu et al.
JSES International
Shoulder Injury and Treatment
article

Improving Bone Mineral Density Assessment in Total Shoulder Arthroplasty: Assessment of Phantom-Calibrated Hounsfield Units in the Glenoid and Proximal Humerus

Saagar Dhanjani, Darryl D. DʼLima, Heinz R. Hoenecke, Clarence Cabatu, Tim Wang, Kishan S. Shah
article en

Abstract

Background: Bone mineral density (BMD) plays a critical role in the success of total shoulder arthroplasty (TSA), as poor bone quality is associated with poor implant fixation, particularly in short stem and stemless designs that rely on metaphyseal fixation.However, Dual-Energy X-ray Absorptiometry (DEXA) scans are not routinely obtained preoperatively.Computed tomography (CT)-derived Hounsfield units (HU) have emerged as a potential surrogate for BMD assessment, but HU values can have high variability, which limits accuracy.Phantom calibration (PC) may standardize HU values, but its benefit in the shoulder remains unclear.This study aimed to compare correlations of standard and PC-HU with DEXA-derived BMD, assess their diagnostic performance with receiver operating characteristic (ROC) analysis, and identify HU thresholds for osteoporosis detection. Materials & Methods:A retrospective analysis was performed on 84 shoulders from 76 patients, with some patients contributing bilateral shoulders.All patients underwent both shoulder CT and DEXA within one year of a TSA.Demographics, clinical information, and behavioral factors were collected.HU values were measured from the glenoid and proximal humerus and were calibrated to mg/cc using a phantom.Correlations between HU and DEXA Tscores in the femoral neck, total hip, and spine were evaluated using Spearman's correlation.ROC curve analysis was used to identify optimal HU thresholds for osteoporosis classification. J o u r n a l P r e -p r o o fResults: Both standard and PC HU (mg/cc) values of the glenoid and proximal humerus significantly correlated with DEXA T-scores (p < 0.001), though standard HU generally demonstrated stronger correlations.Optimal thresholds for identifying osteoporosis were 185.38 for the non-PC glenoid (sensitivity = 83.3%,specificity = 65.7%) and 30.90 for the proximal humerus (sensitivity = 78.6%,specificity = 75%).The PC glenoid threshold of 236.44 yielded slightly higher sensitivity (90.9%) but lower specificity (59.0%).PC proximal humerus HU did not demonstrate significant discriminatory power. Conclusion:The optimal thresholds for identifying osteoporosis were 185.38 HU for the non-PC glenoid, 30.90 HU for the non-PC proximal humerus, and 236.44 mg/cc for the PC glenoid.Both standard and PC HU values of the glenoid and proximal humerus significantly correlated with DEXA T-scores, although standard HU generally showed stronger correlations.These findings suggest that phantom-based calibration at these sites may offer no additional benefit in assessing systemic BMD.

JSES International
Scripps Health (US), Georgetown University (US), Scripps Green Hospital (US), Scripps Clinic (US)
Openalex Percentile: Top 7%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.