ABSTRACT NUMBER: ESOC2026A2028 REMOTE ROBOTIC THROMBECTOMY: FEASIBILITY IN A REGIONAL AND TRANSATLANTIC SETTING IN A LIVE PORCINE MODEL

Abstract Background and aims A substantial proportion of large vessel strokes remain untreated worldwide due to limited access to specialized neuroendovascular care. Remote robotic neuroendovascular thrombectomy performed by expert interventionalists from a distant hub has been proposed as one solution to address these disparities. In this study, we test the feasibility of remote robotic thrombectomy in a live animal model. Methods Two live porcine experiments were conducted, involving Mayo Clinic Arizona (MCA), University Hospital Zurich (USZ), and Inselspital—Bern University Hospital (USB), Switzerland. Aspiration thrombectomy at USB was performed remotely from USZ (regional hub, 95 km; two experiments) and MCA (international hub, one experiment). Five aspiration thrombectomies were completed using a proprietary robotic magnetic navigation system consisting of a mobile magnetic field generator, a three-axis robotic advancer, controlling an 80 cm 6f sheath, a 6f aspiration catheter and a 0.035″ magnetically trackable guidewire, and a teleoperated console. The primary endpoint was the feasibility of successful clot aspiration using the robotic magnetic navigation system. Results Five out of seven thrombectomy procedures were successfully completed, achieving full clot retrieval. In the remaining two procedures, more distal clots were targeted, which could not be reached due to the limited catheter length. Magnetic navigation was successful in all cases. Image quality was excellent to acceptable. Conclusions Remote robotic thrombectomy using robotic magnetic navigation technology is technically feasible over both regional and transcontinental distances. This first-in-vivo regional and transatlantic study establishes a potential model of stroke intervention that may one day bridge access to endovascular stroke treatment. Conflict of interest Patrick Thurner and Tilman Schubert have consulting agreements with Nanoflex Robotics.

Authors

Institutions

Publication Details

Journal
European Stroke Journal
Published
2026-05-01
DOI
https://doi.org/10.1093/esj/aakag023.134
Primary Topic
Soft Robotics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ABSTRACT NUMBER: ESOC2026A2028 REMOTE ROBOTIC THROMBECTOMY: FEASIBILITY IN A REGIONAL AND TRANSATLANTIC SETTING IN A LIVE PORCINE MODEL

Patrick Thurner, Silvan Jungi, T Schubert, Christian Zielasek et al.
European Stroke Journal
Soft Robotics and Applications
article

ABSTRACT NUMBER: ESOC2026A2028 REMOTE ROBOTIC THROMBECTOMY: FEASIBILITY IN A REGIONAL AND TRANSATLANTIC SETTING IN A LIVE PORCINE MODEL

Patrick Thurner, Silvan Jungi, T Schubert, Christian Zielasek, Evelyn Turcotte, Bernard Bendok, Zsolt Kulcsar, Tomas Dobrocky
article en

Abstract

Abstract Background and aims A substantial proportion of large vessel strokes remain untreated worldwide due to limited access to specialized neuroendovascular care. Remote robotic neuroendovascular thrombectomy performed by expert interventionalists from a distant hub has been proposed as one solution to address these disparities. In this study, we test the feasibility of remote robotic thrombectomy in a live animal model. Methods Two live porcine experiments were conducted, involving Mayo Clinic Arizona (MCA), University Hospital Zurich (USZ), and Inselspital—Bern University Hospital (USB), Switzerland. Aspiration thrombectomy at USB was performed remotely from USZ (regional hub, 95 km; two experiments) and MCA (international hub, one experiment). Five aspiration thrombectomies were completed using a proprietary robotic magnetic navigation system consisting of a mobile magnetic field generator, a three-axis robotic advancer, controlling an 80 cm 6f sheath, a 6f aspiration catheter and a 0.035″ magnetically trackable guidewire, and a teleoperated console. The primary endpoint was the feasibility of successful clot aspiration using the robotic magnetic navigation system. Results Five out of seven thrombectomy procedures were successfully completed, achieving full clot retrieval. In the remaining two procedures, more distal clots were targeted, which could not be reached due to the limited catheter length. Magnetic navigation was successful in all cases. Image quality was excellent to acceptable. Conclusions Remote robotic thrombectomy using robotic magnetic navigation technology is technically feasible over both regional and transcontinental distances. This first-in-vivo regional and transatlantic study establishes a potential model of stroke intervention that may one day bridge access to endovascular stroke treatment. Conflict of interest Patrick Thurner and Tilman Schubert have consulting agreements with Nanoflex Robotics.

European Stroke JournalVol. 11(Supplement_1)
University Hospital of Bern (CH), University Hospital of Zurich (CH), Mayo Clinic in Arizona (US), Mayo Clinic Hospital (US)
Openalex Percentile: Top 11%
Soft Robotics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.