Effect of Osteotomy Depth on Intraosseous Temperature During Implant Drilling: A Standardized CAD/CAM-Guided Thermocouple Study

PURPOSE: Heat generation during implant osteotomy may compromise bone vitality. Osteotomy depth and drill diameter are key contributors to intraosseous temperature rise, particularly in dense cortical bone. This in vitro study evaluated the effects of drill diameter and osteotomy depth on maximum intraosseous temperature (Tmax) using standardized thermocouple placement with CAD/CAM-assisted surgical guides. MATERIALS AND METHODS: Fresh bovine femoral cortical bone blocks (D1-like dense cortical model) were used. A 3×3 factorial design included three final drill diameters (3.5, 4.0, 4.5 mm) and three osteotomy depths (6.5, 11, 15 mm). Ten osteotomies were performed per diameter-depth combination (n=90). Two K-type thermocouples were positioned 1 mm from the lateral osteotomy walls at the apical region via 3D-printed guides. Tmax was analyzed using two-way ANOVA with Tukey post-hoc tests, Pearson correlation, and linear regression. RESULTS: Tmax ranged from 33.3 to 41.7 °C and remained below 47 °C in all groups. Depth and diameter showed significant main effects on Tmax (p<0.001), with a stronger effect for depth (F(2,81)=3883.56; η²=0.82) than diameter (F(2,81)=803.44; η²=0.17). The diameter×depth interaction was significant (F(4,81)=11.36; p<0.001). Depth correlated strongly with Tmax (r=0.886; p<0.001), and each 1-mm increase in depth was associated with an approximate 0.63 °C increase in Tmax (R²=0.785; p<0.001). CONCLUSIONS: Osteotomy depth was the dominant determinant of intraosseous temperature rise, whereas drill diameter had a secondary but clinically relevant effect. Under the tested standardized conditions and continuous irrigation, Tmax remained below the classical 47 °C threshold in all groups. These findings reflect a D1-like cortical model and peak-temperature-only assessment; cumulative thermal dose was not evaluated.

Authors

Publication Details

Journal
The International Journal of Oral & Maxillofacial Implants
Published
2026-05-01
DOI
https://doi.org/10.11607/jomi.11735
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Osteotomy Depth on Intraosseous Temperature During Implant Drilling: A Standardized CAD/CAM-Guided Thermocouple Study

Aykut Can Balkanlioglu, İzzet Acikan
The International Journal of Oral & Maxillofacial Implants
Dental Implant Techniques and Outcomes
article

Effect of Osteotomy Depth on Intraosseous Temperature During Implant Drilling: A Standardized CAD/CAM-Guided Thermocouple Study

Aykut Can Balkanlioglu, İzzet Acikan
article en

Abstract

PURPOSE: Heat generation during implant osteotomy may compromise bone vitality. Osteotomy depth and drill diameter are key contributors to intraosseous temperature rise, particularly in dense cortical bone. This in vitro study evaluated the effects of drill diameter and osteotomy depth on maximum intraosseous temperature (Tmax) using standardized thermocouple placement with CAD/CAM-assisted surgical guides. MATERIALS AND METHODS: Fresh bovine femoral cortical bone blocks (D1-like dense cortical model) were used. A 3×3 factorial design included three final drill diameters (3.5, 4.0, 4.5 mm) and three osteotomy depths (6.5, 11, 15 mm). Ten osteotomies were performed per diameter-depth combination (n=90). Two K-type thermocouples were positioned 1 mm from the lateral osteotomy walls at the apical region via 3D-printed guides. Tmax was analyzed using two-way ANOVA with Tukey post-hoc tests, Pearson correlation, and linear regression. RESULTS: Tmax ranged from 33.3 to 41.7 °C and remained below 47 °C in all groups. Depth and diameter showed significant main effects on Tmax (p<0.001), with a stronger effect for depth (F(2,81)=3883.56; η²=0.82) than diameter (F(2,81)=803.44; η²=0.17). The diameter×depth interaction was significant (F(4,81)=11.36; p<0.001). Depth correlated strongly with Tmax (r=0.886; p<0.001), and each 1-mm increase in depth was associated with an approximate 0.63 °C increase in Tmax (R²=0.785; p<0.001). CONCLUSIONS: Osteotomy depth was the dominant determinant of intraosseous temperature rise, whereas drill diameter had a secondary but clinically relevant effect. Under the tested standardized conditions and continuous irrigation, Tmax remained below the classical 47 °C threshold in all groups. These findings reflect a D1-like cortical model and peak-temperature-only assessment; cumulative thermal dose was not evaluated.

The International Journal of Oral & Maxillofacial ImplantsVol. 0(0)
Life below water
Openalex Percentile: Top 5%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Osteotomy Depth on Intraosseous Temperature During Implant Drilling: A Standardized CAD/CAM-Guided Thermocouple Study — Aykut Can Balkanlioglu, İzzet Acikan · The International Journal of Oral & Maxillofacial Implants (2026) | TGRS Research Map | TGRS