Deep Learning Morphometric Analysis on Protocol Biopsies Predicts Future Graft Function
<h2>Abstract</h2><h3>Introduction</h3> The predictive value of Banff Classification in protocol transplant biopsies without specific lesions is limited. Morphometry provides precise data on microstructures, surpassing semi-quantitative scores but is time-consuming. This study evaluates whether automated morphometric analysis with deep learning can predict glomerular filtration rate at three years using machine learning. <h3>Methods</h3> This retrospective study included kidney transplant recipients who underwent protocol biopsy without specific lesion. The models were trained and tested on the Training/Test cohort, with external validation on the Application cohort. Eight deep learning algorithms extracted 23 morphometric parameters from whole-slide images. Ten machine learning models were tested for three years glomerular filtration rates prediction. <h3>Results</h3> A total of 367 patients were included. The means three-year estimated glomerular filtration rates were 53±23 and 53±22 mL/min/1.73m<sup>2</sup> in the Training/Test and Application cohorts, respectively. In the Training/Test cohort, estimated glomerular filtration rate correlated negatively with interstitial fibrosis (r=-0.33; p<0.001), tubular atrophy (r=-0.39; p<0.001), artery luminal stenosis (r=-0.29; p<0.001), and positively with glomerular density (r=0.16; p<0.05) and glomerular epithelial (r=0.33; p<0.001), endothelial (r=0.30; p<0.001), and mesangial (r=0.25; p=0.002) cell densities. Kernel Ridge and Bayesian models achieved the best predictions (Mean Absolute Error=11±1 mL/min/1.73m<sup>2</sup>). External validation showed good association between predicted with Kernel Ridge model and observed estimated glomerular filtration rate (Mean Absolute Error=13±11 mL/min/1.73m<sup>2</sup>, r=0.68; p<0.001). After correction with Bland Altman Bias, paired analysis showed no significant difference between predicted and observed estimated glomerular filtration rates (p=0.953). <h3>Conclusion</h3> Integrating Automated morphometric analyses into machine learning models may help predict glomerular filtration rates three years after protocol biopsies.
Authors
- Jamal Bamoulid (ORCID: https://orcid.org/0000-0002-3487-8685)
- Manon Ansart (ORCID: https://orcid.org/0000-0002-0703-2908)
- Fanny Buron (ORCID: https://orcid.org/0000-0003-0404-6746)
- Rémi Lenain (ORCID: https://orcid.org/0000-0001-6317-9763)
- Jean‐Baptiste Gibier (ORCID: https://orcid.org/0000-0002-1194-5590)
- Alexia Gazeu (ORCID: https://orcid.org/0000-0002-2808-3894)
- Maud Rabeyrin (ORCID: https://orcid.org/0000-0003-0713-3271)
- Michel Paindavoine (ORCID: https://orcid.org/0000-0002-6026-9453)
- Claire Tinel
- Patrick Bard (ORCID: https://orcid.org/0000-0001-5464-4766)
- Georges Tarris (ORCID: https://orcid.org/0000-0002-2901-6618)
- Mehdi Maanaoui (ORCID: https://orcid.org/0000-0001-6188-1196)
- Mathieu Legendre (ORCID: https://orcid.org/0000-0001-8289-3049)
- Sophie Félix
- Laurent Martin
- Mira Ben Haberou
- Sami Ezzahid
- Cécile Picard
- Cécile Courivaud
- Hugo Gabriel Pereira De Almeida
- Alice Koenig
Institutions
- Centre National de la Recherche Scientifique (FR)
- Université de Bourgogne (FR)
- Centre Hospitalier Universitaire de Lille (FR)
- Centre Hospitalier Universitaire de Besançon (FR)
- Hospices Civils de Lyon (FR)
- CHU Dijon Bourgogne (FR)
Publication Details
- Journal
- Kidney International Reports
- Published
- 2026-05-01
- DOI
- https://doi.org/10.1016/j.ekir.2026.106585
- Primary Topic
- Gene expression and cancer classification
- Type
- article
- Field-Weighted Citation Impact
- 0.00