Digital fit and positional trueness analysis of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations

OBJECTIVES: To evaluate the fit and positional trueness of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations. METHODS: A reference maxillary model with a prepared left first molar was digitized to design a reference crown. Resin casts were additively manufactured from the model scan using digital light processing (DLP) or stereolithography (SLA) at 0-, 30-, 45-, and 90-degree build orientations (n = 7). A zirconia crown was fabricated from the reference design and digitized alone and while seated on each cast using an intraoral scanner. Crown fit was assessed using the triple-scan protocol (average gap), and positional trueness was determined by measuring surface deviations (occlusal, buccal, palatal, mesial, and distal) relative to the original design position. Data were statistically analyzed (α = 0.05). RESULTS: The reference crown had the highest average gap when seated on SLA-90, followed by DLP-90 (P < 0.001). Combinations involving the DLP trinomial or 0- and 30-degree orientations generally led to lower positional deviations, whereas those with a 90-degree orientation tended to result in higher deviations (P ≤ 0.033). CONCLUSIONS: Although manufacturing trinomial and build orientation affected fit and positional trueness, average gap values remained below the clinically acceptable threshold except for SLA-90. Higher positional trueness was mostly observed when the crown was seated on DLP casts or casts printed at 0- or 30-degree orientations.

Authors

Institutions

Publication Details

Journal
Journal of Dentistry
Published
2026-05-01
DOI
https://doi.org/10.1016/j.jdent.2026.106737
Primary Topic
Additive Manufacturing Materials and Processes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital fit and positional trueness analysis of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations

Münir Demirel, Almira Ada Diken Türksayar, Bahtınur Şencan, Mustafa Borga Dönmez
Journal of Dentistry
Additive Manufacturing Materials and Processes
article

Digital fit and positional trueness analysis of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations

Münir Demirel, Almira Ada Diken Türksayar, Bahtınur Şencan, Mustafa Borga Dönmez
article en

Abstract

OBJECTIVES: To evaluate the fit and positional trueness of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations. METHODS: A reference maxillary model with a prepared left first molar was digitized to design a reference crown. Resin casts were additively manufactured from the model scan using digital light processing (DLP) or stereolithography (SLA) at 0-, 30-, 45-, and 90-degree build orientations (n = 7). A zirconia crown was fabricated from the reference design and digitized alone and while seated on each cast using an intraoral scanner. Crown fit was assessed using the triple-scan protocol (average gap), and positional trueness was determined by measuring surface deviations (occlusal, buccal, palatal, mesial, and distal) relative to the original design position. Data were statistically analyzed (α = 0.05). RESULTS: The reference crown had the highest average gap when seated on SLA-90, followed by DLP-90 (P < 0.001). Combinations involving the DLP trinomial or 0- and 30-degree orientations generally led to lower positional deviations, whereas those with a 90-degree orientation tended to result in higher deviations (P ≤ 0.033). CONCLUSIONS: Although manufacturing trinomial and build orientation affected fit and positional trueness, average gap values remained below the clinically acceptable threshold except for SLA-90. Higher positional trueness was mostly observed when the crown was seated on DLP casts or casts printed at 0- or 30-degree orientations.

Journal of Dentistry
Biruni University (TR)
Openalex Percentile: Top 11%
Additive Manufacturing Materials and Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Digital fit and positional trueness analysis of a crown seated on additively manufactured casts fabricated using different manufacturing trinomials and build orientations — Münir Demirel, Almira Ada Diken Türksayar, et al. · Journal of Dentistry (2026) | TGRS Research Map | TGRS