An integrated VSG fault ride-through strategy based on reactive power loop and voltage loop reset

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid. However, the GFM inverters during voltage faults are prone to overcurrent issues. To solve this problem, this paper proposes an integrated control strategy based on the reactive power loop and voltage loop reset. This method incorporates reactive power loop reset and other improvement strategies on the basis of the d-axis current limiter, achieving both the rapid current response during faults and the desaturation of the current limiter after fault recovery. Simulation and experimental results verify the correctness of the theory and the effectiveness of the proposed control method.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-05-01
DOI
https://doi.org/10.1049/icp.2026.0718
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An integrated VSG fault ride-through strategy based on reactive power loop and voltage loop reset

J H Li, Xiaolu Zhang, F L Zhang, Xuhui Song et al.
IET conference proceedings.
Microgrid Control and Optimization
article

An integrated VSG fault ride-through strategy based on reactive power loop and voltage loop reset

J H Li, Xiaolu Zhang, F L Zhang, Xuhui Song, Kaixiang Gong
article en

Abstract

Grid-forming (GFM) inverter controls have illustrated many desirable features to enable the bulk integration of renewable resources into the future power grid. However, the GFM inverters during voltage faults are prone to overcurrent issues. To solve this problem, this paper proposes an integrated control strategy based on the reactive power loop and voltage loop reset. This method incorporates reactive power loop reset and other improvement strategies on the basis of the d-axis current limiter, achieving both the rapid current response during faults and the desaturation of the current limiter after fault recovery. Simulation and experimental results verify the correctness of the theory and the effectiveness of the proposed control method.

IET conference proceedings.Vol. 2025(49)
Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 7%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.