Coordinated model predictive control methods for 1000 MW thermal power units based on multi-objective trade-off mechanism

To address the multi-objective dynamic conflict challenges during deep peak shaving of 1000 MW ultra-supercritical thermal power units under high renewable energy integration, including rapid load response, pressure stability, economic operation, and low emissions, this study proposes a Model Predictive Control (MPC) method based on multi-objective trade-off mechanisms. The approach first constructs a simplified linear predictive model for control purposes to capture key unit dynamic characteristics. A comprehensive quadratic objective function integrating four objectives is then established. A fuzzy logic dynamic weight adjustment strategy is introduced to adaptively adjust control priorities according to operating conditions. Within the MPC framework, a rolling optimization problem incorporating input/output amplitude and rate constraints is designed and solved using an efficient quadratic programming solver. A feedback correction mechanism based on actual output continuously refines model prediction errors. Results demonstrate that the proposed method achieves a load tracking root mean square error (RMSE) of 0.093 and a regulation time of 12.29 s, representing 55.9% and 43.2% reductions compared to traditional MPC methods, respectively. Mean main steam pressure fluctuations are reduced by over 29.8% compared to coordinated MPC. Power supply coal consumption rate decreases to 282.7 g/kWh, with nitrogen oxide (NOx) emission concentration reaching 106.5 mg/m 3 . The method effectively resolves multi-objective dynamic conflicts while significantly enhancing unit flexibility, economic efficiency, and environmental performance. • Proposes a coordinated MPC strategy for 1000 MW ultra-supercritical power units with high renewable integration. • Balances load tracking, steam pressure stability, coal consumption, and NOx emissions via a multi-objective model. • Uses fuzzy logic for dynamic weight adjustment and quadratic programming for constrained optimization. • Achieves fast tracking (RMSE 0.093), stable pressure, lower coal use, and reduced NOx emissions.

Authors

Institutions

Publication Details

Journal
Green Technologies and Sustainability
Published
2026-05-01
DOI
https://doi.org/10.1016/j.grets.2026.100407
Primary Topic
Advanced Control Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Coordinated model predictive control methods for 1000 MW thermal power units based on multi-objective trade-off mechanism

Guoxing Wu, Xiaobo Cui, Xuanchen Wu
Green Technologies and Sustainability
Advanced Control Systems Optimization
article

Coordinated model predictive control methods for 1000 MW thermal power units based on multi-objective trade-off mechanism

Guoxing Wu, Xiaobo Cui, Xuanchen Wu
article en

Abstract

To address the multi-objective dynamic conflict challenges during deep peak shaving of 1000 MW ultra-supercritical thermal power units under high renewable energy integration, including rapid load response, pressure stability, economic operation, and low emissions, this study proposes a Model Predictive Control (MPC) method based on multi-objective trade-off mechanisms. The approach first constructs a simplified linear predictive model for control purposes to capture key unit dynamic characteristics. A comprehensive quadratic objective function integrating four objectives is then established. A fuzzy logic dynamic weight adjustment strategy is introduced to adaptively adjust control priorities according to operating conditions. Within the MPC framework, a rolling optimization problem incorporating input/output amplitude and rate constraints is designed and solved using an efficient quadratic programming solver. A feedback correction mechanism based on actual output continuously refines model prediction errors. Results demonstrate that the proposed method achieves a load tracking root mean square error (RMSE) of 0.093 and a regulation time of 12.29 s, representing 55.9% and 43.2% reductions compared to traditional MPC methods, respectively. Mean main steam pressure fluctuations are reduced by over 29.8% compared to coordinated MPC. Power supply coal consumption rate decreases to 282.7 g/kWh, with nitrogen oxide (NOx) emission concentration reaching 106.5 mg/m 3 . The method effectively resolves multi-objective dynamic conflicts while significantly enhancing unit flexibility, economic efficiency, and environmental performance. • Proposes a coordinated MPC strategy for 1000 MW ultra-supercritical power units with high renewable integration. • Balances load tracking, steam pressure stability, coal consumption, and NOx emissions via a multi-objective model. • Uses fuzzy logic for dynamic weight adjustment and quadratic programming for constrained optimization. • Achieves fast tracking (RMSE 0.093), stable pressure, lower coal use, and reduced NOx emissions.

Green Technologies and Sustainability
Nanning Normal University (CN), Changzhou Architectural Research Institute Group (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 7%
Advanced Control Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.