Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

Abstract The combination of a Cherenkov radiator with a semi transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15 ps. While tileable prototypes with 10×10 channels feature 1 × 1 cm 2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5 mm spatial resolution with 3.5 mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2 mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20 ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

Authors

Publication Details

Journal
Journal of Instrumentation
Published
2026-05-01
DOI
https://doi.org/10.1088/1748-0221/21/05/p05003
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

S. White, A. Kallitsopoulou, M. Lisowska, X. W. Wang et al.
Journal of Instrumentation
Particle Detector Development and Performance
article

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

S. White, A. Kallitsopoulou, M. Lisowska, X. W. Wang, E. Oliveri, J.J. Liu, Q. Huang, G. Fanourakis, P. Vitulo, D. Desforge, I. Giomataris, D. Fiorina, K. Salamon, L. Sohl, T. Papaevangelou, F.M. Brunbauer, S. Aune, D. Janssens, Y. Angelis, M. Brunoldi, P. Legou, T. Schneider, D. Sampsonidis, S.E. Tzamarias, N. Shankman, M. Micetic, J. Datta, I. Vai, Y. Tsipolitis, I. Maniatis, E. Scorsone, I. Karakoulias, F. Garcia, F.J. Iguaz, K. Gnanvo, M. van Stenis, K.J. Floethner, Z.Y. Zhang, R. Veenhof, R. Aleksan, M. Kovacic, L. Scharenberg, J. Bortfeldt, M. Pomorski, M. Lupberger, H. Muller, L. Ropelewski, A. Utrobicic, Y.Z. Zhou, M. Gallinaro
article en

Abstract

Abstract The combination of a Cherenkov radiator with a semi transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15 ps. While tileable prototypes with 10×10 channels feature 1 × 1 cm 2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5 mm spatial resolution with 3.5 mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2 mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20 ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

Journal of InstrumentationVol. 21(05)
Openalex Percentile: Top 7%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.