ABSTRACT NUMBER: ESOC2026A312 CARDIAC PHOTON-COUNTING DETECTOR COMPUTED TOMOGRAPHY IN ACUTE ISCHEMIC STROKE: DIAGNOSTIC ACCURACY FOR DETECTION OF LEFT ATRIAL APPENDAGE THROMBUS

Abstract Background and aims In up to 1/3 of ischemic stroke patients no cause can be identified. Left atrial appendage (LAA) is the primary anatomical origin of cardiac embolism, yet it is often inadequately assessed in stroke etiological workup. The goal of this study was to analyse the diagnostic accuracy of cardiac photon-counting detector computed tomography (PCD-CT) integrated in the hyperacute stroke imaging protocol for detection of LAA thrombus. Methods We conducted a retrospective diagnostic accuracy study of consecutive patients with acute ischemic stroke or transient ischemic attack undergoing emergent cardiac PCD-CT and transoesophageal echocardiography (TEE) between 2023-2025. Cardiac PCD-CT and TEE were assessed for detection of LAA thrombus. Patients with and without LAA thrombus (defined by PCD-CT) were compared. Diagnostic performance metrics for cardiac PCD-CT for LAA thrombus detection were calculated using TEE as gold-standard. Results We included 101 patients, 42 were female (42%), median age was 59 years, 87 patients had acute ischemic stroke (86%). Median time between cardiac PCD-CT and TEE was 2 days. LAA thrombus defined by PCD-CT was present in 12 patients (12%). Patients with LAA thrombus were older (74 versus 58 years, p<0.001) and more frequently had atrial fibrillation (83.3% versus 23.6%, p<0.001). Diagnostic accuracy of PCD-CT was 96% (95% confidence interval [95%CI]=90-99%), sensitivity was 90% (95%CI=56-100), specificity was 97% (95%CI=91-99%), positive predictive value was 75% (95%CI=49-90%) and negative predictive value was 99% (95%CI=93-100%). Conclusions Cardiac PCD-CT integrated as part of the acute stroke imaging protocol has an excellent diagnostic accuracy for detecting LAA thrombi. Conflict of interest Annemarie Kirschfink: nothing to disclose. Mohamed Elhalal: nothing to disclose. Stefan Seidel: nothing to disclose. Stefanie Kammer: nothing to disclose. Dimah Hasan: nothing to disclose. Michael Frick: nothing to disclose. Nikolaus Marx: nothing to disclose. Jörg B. Schulz: nothing to disclose. Martin Wiesmann: nothing to disclose. Ertunc Altiok: nothing to disclose. Hani Ridwan: nothing to disclose Arno Reich: nothing to disclose. João Pinho: nothing to disclose

Authors

Institutions

Publication Details

Journal
European Stroke Journal
Published
2026-05-01
DOI
https://doi.org/10.1093/esj/aakag023.246
Primary Topic
Atrial Fibrillation Management and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ABSTRACT NUMBER: ESOC2026A312 CARDIAC PHOTON-COUNTING DETECTOR COMPUTED TOMOGRAPHY IN ACUTE ISCHEMIC STROKE: DIAGNOSTIC ACCURACY FOR DETECTION OF LEFT ATRIAL APPENDAGE THROMBUS

Ertunc Altiok, Hani Ridwan, Michael Frick, M Wiesmann et al.
European Stroke Journal
Atrial Fibrillation Management and Outcomes
article

ABSTRACT NUMBER: ESOC2026A312 CARDIAC PHOTON-COUNTING DETECTOR COMPUTED TOMOGRAPHY IN ACUTE ISCHEMIC STROKE: DIAGNOSTIC ACCURACY FOR DETECTION OF LEFT ATRIAL APPENDAGE THROMBUS

Ertunc Altiok, Hani Ridwan, Michael Frick, M Wiesmann, Annemarie Kirschfink, Dimah Hasan, Stefan Seidel, Stefanie Kammer, João Pinho, Arno Reich, Jörg B Schulz, Mohamed Elhalal, Nikolaus Marx
article en

Abstract

Abstract Background and aims In up to 1/3 of ischemic stroke patients no cause can be identified. Left atrial appendage (LAA) is the primary anatomical origin of cardiac embolism, yet it is often inadequately assessed in stroke etiological workup. The goal of this study was to analyse the diagnostic accuracy of cardiac photon-counting detector computed tomography (PCD-CT) integrated in the hyperacute stroke imaging protocol for detection of LAA thrombus. Methods We conducted a retrospective diagnostic accuracy study of consecutive patients with acute ischemic stroke or transient ischemic attack undergoing emergent cardiac PCD-CT and transoesophageal echocardiography (TEE) between 2023-2025. Cardiac PCD-CT and TEE were assessed for detection of LAA thrombus. Patients with and without LAA thrombus (defined by PCD-CT) were compared. Diagnostic performance metrics for cardiac PCD-CT for LAA thrombus detection were calculated using TEE as gold-standard. Results We included 101 patients, 42 were female (42%), median age was 59 years, 87 patients had acute ischemic stroke (86%). Median time between cardiac PCD-CT and TEE was 2 days. LAA thrombus defined by PCD-CT was present in 12 patients (12%). Patients with LAA thrombus were older (74 versus 58 years, p<0.001) and more frequently had atrial fibrillation (83.3% versus 23.6%, p<0.001). Diagnostic accuracy of PCD-CT was 96% (95% confidence interval [95%CI]=90-99%), sensitivity was 90% (95%CI=56-100), specificity was 97% (95%CI=91-99%), positive predictive value was 75% (95%CI=49-90%) and negative predictive value was 99% (95%CI=93-100%). Conclusions Cardiac PCD-CT integrated as part of the acute stroke imaging protocol has an excellent diagnostic accuracy for detecting LAA thrombi. Conflict of interest Annemarie Kirschfink: nothing to disclose. Mohamed Elhalal: nothing to disclose. Stefan Seidel: nothing to disclose. Stefanie Kammer: nothing to disclose. Dimah Hasan: nothing to disclose. Michael Frick: nothing to disclose. Nikolaus Marx: nothing to disclose. Jörg B. Schulz: nothing to disclose. Martin Wiesmann: nothing to disclose. Ertunc Altiok: nothing to disclose. Hani Ridwan: nothing to disclose Arno Reich: nothing to disclose. João Pinho: nothing to disclose

European Stroke JournalVol. 11(Supplement_1)
RWTH Aachen University (DE)
Openalex Percentile: Top 8%
Atrial Fibrillation Management and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.