Effect of Cooling Centres on BDNF and HSP70 Responses During a Simulated Heatwave Exposure in Older Adults

Cooling centres are widely recommended to protect older adults and other vulnerable populations from the heat. While there is emerging evidence that cooling centres limit physiological strain, limited data exist on their impact on biomarkers such as brain-derived neurotrophic factor (BDNF) and heat shock protein 70 (HSP70), which are implicated in stress adaptation and neuroprotection. We investigated the effects of a 2-h cooling intervention during a 9-h simulated heatwave on serum BDNF and HSP70 concentrations in older adults. Thirty-six adults aged 64-79 years were assigned to either a control group (n=17) or a cooling group (n=19). The cooling group rested in air-conditioning (~23°C) during hours 5-6, while controls remained in the heat (heat index: 37°C). Serum BDNF and HSP70 were measured at baseline and end-exposure. Analysis of covariance was used to evaluate end-exposure biomarker concentrations, adjusting for baseline and physiological covariates, including thermal strain (area under the curve of core temperature), cardiovascular (heart rate, blood pressure), and autonomic function (root mean square of successive differences [RMSSD]). Cooling led to significantly lower end-exposure BDNF concentrations than controls (β=-595.0 pg/mL, 95% CI:-1162.7 to -27.4, p=0.041), while HSP70 remained unchanged (p=0.779). BDNF was associated with thermal strain (β=177.8 pg/mL per °C·h, p=0.022), and RMSSD (β=22.5 pg/mL per ms, p=0.009). These findings demonstrate that a brief cooling break attenuates stress-related BDNF upregulation in older adults, with circulating BDNF reflecting cumulative thermal load and autonomic function rather than reduced neuroprotection.

Authors

Institutions

Publication Details

Journal
Applied Physiology Nutrition and Metabolism
Published
2026-04-29
DOI
https://doi.org/10.1139/apnm-2025-0443
Primary Topic
Thermoregulation and physiological responses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Cooling Centres on BDNF and HSP70 Responses During a Simulated Heatwave Exposure in Older Adults

Robert D. Meade, Joel Garrett, Kelli E. King, James J. McCormick et al.
Applied Physiology Nutrition and Metabolism
Thermoregulation and physiological responses
article

Effect of Cooling Centres on BDNF and HSP70 Responses During a Simulated Heatwave Exposure in Older Adults

Robert D. Meade, Joel Garrett, Kelli E. King, James J. McCormick, Fergus O'Connor, Glen P. Kenny
article en

Abstract

Cooling centres are widely recommended to protect older adults and other vulnerable populations from the heat. While there is emerging evidence that cooling centres limit physiological strain, limited data exist on their impact on biomarkers such as brain-derived neurotrophic factor (BDNF) and heat shock protein 70 (HSP70), which are implicated in stress adaptation and neuroprotection. We investigated the effects of a 2-h cooling intervention during a 9-h simulated heatwave on serum BDNF and HSP70 concentrations in older adults. Thirty-six adults aged 64-79 years were assigned to either a control group (n=17) or a cooling group (n=19). The cooling group rested in air-conditioning (~23°C) during hours 5-6, while controls remained in the heat (heat index: 37°C). Serum BDNF and HSP70 were measured at baseline and end-exposure. Analysis of covariance was used to evaluate end-exposure biomarker concentrations, adjusting for baseline and physiological covariates, including thermal strain (area under the curve of core temperature), cardiovascular (heart rate, blood pressure), and autonomic function (root mean square of successive differences [RMSSD]). Cooling led to significantly lower end-exposure BDNF concentrations than controls (β=-595.0 pg/mL, 95% CI:-1162.7 to -27.4, p=0.041), while HSP70 remained unchanged (p=0.779). BDNF was associated with thermal strain (β=177.8 pg/mL per °C·h, p=0.022), and RMSSD (β=22.5 pg/mL per ms, p=0.009). These findings demonstrate that a brief cooling break attenuates stress-related BDNF upregulation in older adults, with circulating BDNF reflecting cumulative thermal load and autonomic function rather than reduced neuroprotection.

Applied Physiology Nutrition and Metabolism
Griffith University (AU), Massachusetts Department of Public Health (US), Harvard University (US), University of Ottawa (CA), Ottawa Hospital (CA), Ottawa Hospital Research Institute (CA)
Openalex Percentile: Top 9%
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.