Low-cost thermistor electrodes for numbering-up thermodynamic studies on electroactive biofilms

First bioelectrocalorimetric investigations of Geobacter enrichment biofilms performing extracellular electron transfer (EET) revealed the microbial electrochemical Peltier heat ( Π m ) as an entropic barrier leading to energy losses. Like its abiotic analog, Π m can be assumed to be a material constant, depending on the redox species performing EET, the working electrode material, and the electrolyte composition. To foster bioelectrocalorimetric research, a thermistor electrode setup was developed for determining Π m . Thermistor electrodes can be easily numbered up and hence allow systematic thermodynamic studies of the consequences of Π m on the energy balances of electroactive microorganisms and microbial electrochemical technologies. Thermistor electrodes were calibrated by applying defined heat pulses, resulting in a heat transfer coefficient K (0.595 ± 0.303 W K −1 ) and a heat capacity m C p (78.057 ± 28.705 J K −1 ). Subsequently, Π m of Geobacter enrichment biofilms cultivated on gold thermistor electrodes was measured, and the obtained Π m = 16.6 kJ e-mol −1 is comparable to values determined using an established bioelectrocalorimetric setup. This proof-of-concept lays the foundation for optimizing thermistor electrodes to systematically investigate and engineer the energy fluxes at the interface of electroactive microorganisms and electrodes. • Low-cost Thermistor electrodes allow systematic studies on the microbial electrochemical Peltier heat Π m . • Thermistor electrodes were calibrated with defined heat pulses. • Π m amounted to 16.6 kJ mol −1 for Geobacter enrichment biofilms at gold electrodes. • Obtained Π m is comparable to bioelectrocalorimetric studies. • Reactor optimization is required to improve signal stability and sensitivity.

Authors

Institutions

Publication Details

Journal
Electrochemistry Communications
Published
2026-05-01
DOI
https://doi.org/10.1016/j.elecom.2026.108188
Primary Topic
thermodynamics and calorimetric analyses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-cost thermistor electrodes for numbering-up thermodynamic studies on electroactive biofilms

Benjamin Korth, Yvonne Schößow, Falk Harnisch
Electrochemistry Communications
thermodynamics and calorimetric analyses
article

Low-cost thermistor electrodes for numbering-up thermodynamic studies on electroactive biofilms

Benjamin Korth, Yvonne Schößow, Falk Harnisch
article en

Abstract

First bioelectrocalorimetric investigations of Geobacter enrichment biofilms performing extracellular electron transfer (EET) revealed the microbial electrochemical Peltier heat ( Π m ) as an entropic barrier leading to energy losses. Like its abiotic analog, Π m can be assumed to be a material constant, depending on the redox species performing EET, the working electrode material, and the electrolyte composition. To foster bioelectrocalorimetric research, a thermistor electrode setup was developed for determining Π m . Thermistor electrodes can be easily numbered up and hence allow systematic thermodynamic studies of the consequences of Π m on the energy balances of electroactive microorganisms and microbial electrochemical technologies. Thermistor electrodes were calibrated by applying defined heat pulses, resulting in a heat transfer coefficient K (0.595 ± 0.303 W K −1 ) and a heat capacity m C p (78.057 ± 28.705 J K −1 ). Subsequently, Π m of Geobacter enrichment biofilms cultivated on gold thermistor electrodes was measured, and the obtained Π m = 16.6 kJ e-mol −1 is comparable to values determined using an established bioelectrocalorimetric setup. This proof-of-concept lays the foundation for optimizing thermistor electrodes to systematically investigate and engineer the energy fluxes at the interface of electroactive microorganisms and electrodes. • Low-cost Thermistor electrodes allow systematic studies on the microbial electrochemical Peltier heat Π m . • Thermistor electrodes were calibrated with defined heat pulses. • Π m amounted to 16.6 kJ mol −1 for Geobacter enrichment biofilms at gold electrodes. • Obtained Π m is comparable to bioelectrocalorimetric studies. • Reactor optimization is required to improve signal stability and sensitivity.

Electrochemistry Communications
Helmholtz Centre for Environmental Research (DE)
Openalex Percentile: Top 8%
thermodynamics and calorimetric analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Low-cost thermistor electrodes for numbering-up thermodynamic studies on electroactive biofilms — Benjamin Korth, Yvonne Schößow, et al. · Electrochemistry Communications (2026) | TGRS Research Map | TGRS