A modified turn-up anastomotic technique for total arch replacement: the "frill-necked lizard" configuration

BACKGROUND: Secure distal anastomosis is the critical determinant of success in total arch replacement (TAR). We aimed to examine the outcomes of a turn-up technique for TAR and introduced a modified turn up method with graft like frill-necked lizard for distal anastomosis, which provides secure anastomosis under excellent visualization, regardless of underlying pathology or the use of a frozen elephant trunk (FET). METHODS: We retrospectively evaluated 228 consecutive patients who underwent TAR for 119 thoracic aortic aneurysms (TAA) and 109 acute aortic dissections (AAD) between January 2013 and January 2024. We initially used the turn-up method for distal anastomosis. More recently, we have adopted a modified turn-up method with a frill-necked graft. We evaluated overall surgical outcomes of TAR and performed a comparative analysis between patients with TAA and AAD. Circulatory arrest time during distal anastomosis with the modified turn-up technique was compared with that of the conventional turn-up technique. RESULTS: For all patients, the operation, cardiopulmonary bypass, aortic cross-clamp, and lower body circulatory arrest times were 376.2±81.7, 229.3±56.1, 148.6±47.1, and 52.4±16.5 minutes. The circulatory arrest times required for distal anastomosis were 53.1±15.9 and 51.6±17.2 minutes in the TAA and AAD groups. The overall 30-day mortality was 3.1%. The permanent neurological dysfunction rate was 5.7%. Spinal cord complications included three cases of paraparesis; there was no case of paraplegia. Kaplan-Meier survival analysis showed an overall 5-year survival rate of 87.6%. Circulatory arrest time was significantly shorter in the modified turn-up group compared with the conventional turn-up group (34.4 ± 9.4 min vs. 53.9 ± 16.1 min, P<0.01). CONCLUSIONS: The turn-up technique provides secure distal anastomosis regardless of the pathology or FET use and the frill-necked graft facilitates distal anastomosis.

Authors

Institutions

Publication Details

Journal
The Journal of Cardiovascular Surgery
Published
2026-05-01
DOI
https://doi.org/10.23736/s0021-9509.26.13551-4
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A modified turn-up anastomotic technique for total arch replacement: the "frill-necked lizard" configuration

Daisuke Futagami, Hironobu Morimoto, S Watanabe, Yuki Echie et al.
The Journal of Cardiovascular Surgery
Aortic Disease and Treatment Approaches
article

A modified turn-up anastomotic technique for total arch replacement: the "frill-necked lizard" configuration

Daisuke Futagami, Hironobu Morimoto, S Watanabe, Yuki Echie, Shogo MUKAI, Takashi HARADA, Keijiro KATAYAMA
article en

Abstract

BACKGROUND: Secure distal anastomosis is the critical determinant of success in total arch replacement (TAR). We aimed to examine the outcomes of a turn-up technique for TAR and introduced a modified turn up method with graft like frill-necked lizard for distal anastomosis, which provides secure anastomosis under excellent visualization, regardless of underlying pathology or the use of a frozen elephant trunk (FET). METHODS: We retrospectively evaluated 228 consecutive patients who underwent TAR for 119 thoracic aortic aneurysms (TAA) and 109 acute aortic dissections (AAD) between January 2013 and January 2024. We initially used the turn-up method for distal anastomosis. More recently, we have adopted a modified turn-up method with a frill-necked graft. We evaluated overall surgical outcomes of TAR and performed a comparative analysis between patients with TAA and AAD. Circulatory arrest time during distal anastomosis with the modified turn-up technique was compared with that of the conventional turn-up technique. RESULTS: For all patients, the operation, cardiopulmonary bypass, aortic cross-clamp, and lower body circulatory arrest times were 376.2±81.7, 229.3±56.1, 148.6±47.1, and 52.4±16.5 minutes. The circulatory arrest times required for distal anastomosis were 53.1±15.9 and 51.6±17.2 minutes in the TAA and AAD groups. The overall 30-day mortality was 3.1%. The permanent neurological dysfunction rate was 5.7%. Spinal cord complications included three cases of paraparesis; there was no case of paraplegia. Kaplan-Meier survival analysis showed an overall 5-year survival rate of 87.6%. Circulatory arrest time was significantly shorter in the modified turn-up group compared with the conventional turn-up group (34.4 ± 9.4 min vs. 53.9 ± 16.1 min, P<0.01). CONCLUSIONS: The turn-up technique provides secure distal anastomosis regardless of the pathology or FET use and the frill-necked graft facilitates distal anastomosis.

The Journal of Cardiovascular Surgery
Fukuyama City Hospital (JP), Fukuyama Cardiovascular Hospital (JP)
Good health and well-being
Openalex Percentile: Top 7%
Aortic Disease and Treatment Approaches
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.