Analysis and disposal of ecessive nitrogen consumption

The nitrogen pressure stabilization system is the core support of the valve cooling system for HVDC transmission. It can precisely maintain a constant pressure in the valve cooling circuit, prevent cavitation and boiling of the cooling medium to ensure heat dissipation efficiency, and also isolate air to prevent metal corrosion and impurities from invading. It directly affects the safety of the converter valve and the stability of the DC system. If the nitrogen consumption is too fast, it will disrupt the pressure balance, cause heat dissipation failure and accelerated corrosion. In severe cases, it may even cause the DC system to shut down. Therefore, analyzing and addressing this issue is necessary. It can identify the sources of leakage and equipment failures, formulate targeted solutions to prevent the expansion of faults, and ensure the reliable operation of the system and the safety of cross-regional energy transmission.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-05-01
DOI
https://doi.org/10.1049/icp.2026.0716
Primary Topic
High-Voltage Power Transmission Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and disposal of ecessive nitrogen consumption

Shan Shi, WU Xinwen, LianLian Xingwen, Liang Xianrun et al.
IET conference proceedings.
High-Voltage Power Transmission Systems
article

Analysis and disposal of ecessive nitrogen consumption

Shan Shi, WU Xinwen, LianLian Xingwen, Liang Xianrun, Zhang Qiang, Ding Binghou, Xu Song
article en

Abstract

The nitrogen pressure stabilization system is the core support of the valve cooling system for HVDC transmission. It can precisely maintain a constant pressure in the valve cooling circuit, prevent cavitation and boiling of the cooling medium to ensure heat dissipation efficiency, and also isolate air to prevent metal corrosion and impurities from invading. It directly affects the safety of the converter valve and the stability of the DC system. If the nitrogen consumption is too fast, it will disrupt the pressure balance, cause heat dissipation failure and accelerated corrosion. In severe cases, it may even cause the DC system to shut down. Therefore, analyzing and addressing this issue is necessary. It can identify the sources of leakage and equipment failures, formulate targeted solutions to prevent the expansion of faults, and ensure the reliable operation of the system and the safety of cross-regional energy transmission.

IET conference proceedings.Vol. 2025(49)
Yunnan Environmental Protection Bureau (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
High-Voltage Power Transmission Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.