FilmQADose: Open‐source software for radiochromic film dosimetry

PURPOSE: FilmQADose is an open-source, Python-based software for radiochromic film dosimetry, designed to provide medical physicists with a freely available, extensible tool for two-dimensional dose verification in radiotherapy. It covers the full film QA workflow, from calibration curve generation to plan-to-film comparison, targeting clinical and research centers that require an accessible alternative to commercial solutions. DEVELOPMENT AND VALIDATION METHODS: The software was developed in Python using open-source scientific libraries for image processing, curve fitting, DICOM handling, and gamma analysis. Core functionalities include rational and polynomial calibration models, multichannel dose reconstruction, normalized cross-correlation template matching for automatic alignment, and gamma analysis. Validation was performed using irradiated Gafchromic EBT3 films in square field, pyramidal, and breast IMRT plans. Measured dose maps were compared against treatment planning system calculations using 3%/3 mm gamma criteria. DATA FORMAT AND USAGE NOTES: FilmQADose processes TIFF images acquired from flatbed scanners and DICOM RT Dose files exported from treatment planning systems. Output dose maps are generated in DICOM 2D format. The software is implemented in Python with standard scientific Python dependencies and includes a graphical user interface built using PySide6. The source code, documentation, and usage guides are publicly available at: eduardoh27.github.io/FilmQADose. POTENTIAL APPLICATIONS: The software supports clinical quality assurance in IMRT dose verification, as well as for research applications in radiochromic film dosimetry methodology. A limitation is the absence of lateral response artifact correction and recent machine-learning-based calibration methods.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2026-05-01
DOI
https://doi.org/10.1002/acm2.70602
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FilmQADose: Open‐source software for radiochromic film dosimetry

Jaider Vásquez, Eduardo Herrera-Alba, Carlos Ávila, Juliana Sandoval‐Navia et al.
Journal of Applied Clinical Medical Physics
Advanced Radiotherapy Techniques
article

FilmQADose: Open‐source software for radiochromic film dosimetry

Jaider Vásquez, Eduardo Herrera-Alba, Carlos Ávila, Juliana Sandoval‐Navia, Carlos Contreras‐Quiroz
article en

Abstract

PURPOSE: FilmQADose is an open-source, Python-based software for radiochromic film dosimetry, designed to provide medical physicists with a freely available, extensible tool for two-dimensional dose verification in radiotherapy. It covers the full film QA workflow, from calibration curve generation to plan-to-film comparison, targeting clinical and research centers that require an accessible alternative to commercial solutions. DEVELOPMENT AND VALIDATION METHODS: The software was developed in Python using open-source scientific libraries for image processing, curve fitting, DICOM handling, and gamma analysis. Core functionalities include rational and polynomial calibration models, multichannel dose reconstruction, normalized cross-correlation template matching for automatic alignment, and gamma analysis. Validation was performed using irradiated Gafchromic EBT3 films in square field, pyramidal, and breast IMRT plans. Measured dose maps were compared against treatment planning system calculations using 3%/3 mm gamma criteria. DATA FORMAT AND USAGE NOTES: FilmQADose processes TIFF images acquired from flatbed scanners and DICOM RT Dose files exported from treatment planning systems. Output dose maps are generated in DICOM 2D format. The software is implemented in Python with standard scientific Python dependencies and includes a graphical user interface built using PySide6. The source code, documentation, and usage guides are publicly available at: eduardoh27.github.io/FilmQADose. POTENTIAL APPLICATIONS: The software supports clinical quality assurance in IMRT dose verification, as well as for research applications in radiochromic film dosimetry methodology. A limitation is the absence of lateral response artifact correction and recent machine-learning-based calibration methods.

Journal of Applied Clinical Medical PhysicsVol. 27(5)
Universidad de Los Andes (CO), Instituto Nacional de Cancerología (CO)
Openalex Percentile: Top 8%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.