Analysis of the influence of transmission lines on the hundreds of kilohertz harmonics of MMC-HVDC transmission systems

High voltage direct current (HVDC) transmission based on modular multilevel converter (MMC) is the foundation of voltage-sourced converter (VSC-HVDC) transmission, offering superior control and high efficiency, yet it faces persistent harmonic issues. Sustained ultra-high-frequency harmonics (100kHz to several MHz) can cause localized overheating, insulation breakdown, and reduced equipment lifespan, ultimately compromising system reliability. To ensure more stable operation of power systems, this paper establishes an electromagnetic transient simulation model of the MMC-HVDC system. Based on this model, the time-domain waveforms of high-frequency ground harmonic currents at wall bushings and transformer bushings under different transmission line conditions (length, type, and voltage level) are investigated, and their frequency-domain characteristics are analyzed through Fourier transform. Through theoretical derivation and simulation verification, th e influence of transmission lines on high-frequency harmonics in the hundreds-of-kilohertz band is summarized. The research results provide theoretical support and practical guidance for engineering design.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-05-01
DOI
https://doi.org/10.1049/icp.2026.0725
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the influence of transmission lines on the hundreds of kilohertz harmonics of MMC-HVDC transmission systems

X J Liu, Yongfan Guo, Yiru Zhao, Lei Qi et al.
IET conference proceedings.
HVDC Systems and Fault Protection
article

Analysis of the influence of transmission lines on the hundreds of kilohertz harmonics of MMC-HVDC transmission systems

X J Liu, Yongfan Guo, Yiru Zhao, Lei Qi, Zhenyong Chen, Bin Yuan, Hong Shen, Wenxi Zhen
article en

Abstract

High voltage direct current (HVDC) transmission based on modular multilevel converter (MMC) is the foundation of voltage-sourced converter (VSC-HVDC) transmission, offering superior control and high efficiency, yet it faces persistent harmonic issues. Sustained ultra-high-frequency harmonics (100kHz to several MHz) can cause localized overheating, insulation breakdown, and reduced equipment lifespan, ultimately compromising system reliability. To ensure more stable operation of power systems, this paper establishes an electromagnetic transient simulation model of the MMC-HVDC system. Based on this model, the time-domain waveforms of high-frequency ground harmonic currents at wall bushings and transformer bushings under different transmission line conditions (length, type, and voltage level) are investigated, and their frequency-domain characteristics are analyzed through Fourier transform. Through theoretical derivation and simulation verification, th e influence of transmission lines on high-frequency harmonics in the hundreds-of-kilohertz band is summarized. The research results provide theoretical support and practical guidance for engineering design.

IET conference proceedings.Vol. 2025(49)
North China Electric Power University (CN), Primary Source (US), Economic Research Institute (BG), State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources
Openalex Percentile: Top 10%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.