Aggregate model of large-scale parallel grid-forming inverters for converter-driven stability analysis

• Accurate 2-aggregate inverter model for large-scale inverter-based plants. • A single-inverter model cannot represent inverter-to-inverter interactions. • Inverter-to-grid and inverter-to-inverter resonances arise in large-scale plants. • The proposed model considers parameter dispersion focusing on stability analysis. • Validation against accurate EMT simulations considering parameter dispersion. The increasing share of renewable energy plants is transforming power systems into inverter-dominated grids with low inertia and weak-grid conditions. Grid-Forming (GFM) inverters can address these challenges by emulating the dynamics of synchronous generators; however, large-scale GFM plants introduce complex multi-inverter and grid interactions that are not yet fully understood. This paper proposes a reduced order but high-fidelity aggregate model for large-scale GFM plants, capable of representing both plant-to-grid and internal inverter-to-inverter resonances while considering parameter dispersion among inverters for converter-driven stability analysis. The model is specifically designed for the planning and diagnosis of resonances occurring at the normal operating point in grids with a high penetration of GFM resources. Cross-validation against detailed averaged electromagnetic transient simulations confirm that the proposed 2-AggGFM model accurately reproduces the critical dynamic behavior of multi-inverter plants, including resonance excitability from grid and inverter perturbations. These results demonstrate its effectiveness as a practical and efficient model for converter-driven stability assessment and control-oriented design in large-scale inverter-based grids.

Authors

Institutions

Publication Details

Journal
International Journal of Electrical Power & Energy Systems
Published
2026-05-01
DOI
https://doi.org/10.1016/j.ijepes.2026.111899
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Aggregate model of large-scale parallel grid-forming inverters for converter-driven stability analysis

Naiara Goñi, Luis Marroyo, Miguel García, A. Garcı́a et al.
International Journal of Electrical Power & Energy Systems
Microgrid Control and Optimization
article

Aggregate model of large-scale parallel grid-forming inverters for converter-driven stability analysis

Naiara Goñi, Luis Marroyo, Miguel García, A. Garcı́a, Javier Marcos, Guillermo Bautista
article en

Abstract

• Accurate 2-aggregate inverter model for large-scale inverter-based plants. • A single-inverter model cannot represent inverter-to-inverter interactions. • Inverter-to-grid and inverter-to-inverter resonances arise in large-scale plants. • The proposed model considers parameter dispersion focusing on stability analysis. • Validation against accurate EMT simulations considering parameter dispersion. The increasing share of renewable energy plants is transforming power systems into inverter-dominated grids with low inertia and weak-grid conditions. Grid-Forming (GFM) inverters can address these challenges by emulating the dynamics of synchronous generators; however, large-scale GFM plants introduce complex multi-inverter and grid interactions that are not yet fully understood. This paper proposes a reduced order but high-fidelity aggregate model for large-scale GFM plants, capable of representing both plant-to-grid and internal inverter-to-inverter resonances while considering parameter dispersion among inverters for converter-driven stability analysis. The model is specifically designed for the planning and diagnosis of resonances occurring at the normal operating point in grids with a high penetration of GFM resources. Cross-validation against detailed averaged electromagnetic transient simulations confirm that the proposed 2-AggGFM model accurately reproduces the critical dynamic behavior of multi-inverter plants, including resonance excitability from grid and inverter perturbations. These results demonstrate its effectiveness as a practical and efficient model for converter-driven stability assessment and control-oriented design in large-scale inverter-based grids.

International Journal of Electrical Power & Energy SystemsVol. 178
Universidad Pública de Navarra (UPNA) (ES), National Renewable Energy Centre (ES)
Gobierno de Navarra, Agencia Estatal de Investigación
Affordable and clean energy
Openalex Percentile: Top 8%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.