Low voltage ride-through strategy for sending-end AC faults in a wind power-gravity energy storage integrated system via VSC-HVDC transmission

Flexible HVDC transmission based on modular multilevel converters (MMCs) is a mainstream solution for integrating large-scale wind power over long distances. However, the sending end of such systems lacks strong grid support, making it susceptible to overvoltage and overcurrent issues during asymmetric AC faults. This paper investigates the transient characteristics and control strategies for such faults in an MMC-HVDC system integrated with gravity energy storage (GES) on the wind farm side. The limitations of conventional negative-sequence current suppression strategies are analysed, highlighting their tendency to cause overvoltage in healthy phases and delayed post-fault voltage recovery. An optimised negative-sequence current control strategy is proposed, wherein the sending-end MMC proactively injects a controlled amount of negative-sequence current to limit fault current magnitude. This is synergised with the rapid power support capability of the GES to facilitate voltage recovery. Simulation results conducted in PSCAD/EMTDC validate the effectiveness and superiority of the proposed strategy in enhancing the system's fault ride-through capability.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-05-01
DOI
https://doi.org/10.1049/icp.2026.0723
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low voltage ride-through strategy for sending-end AC faults in a wind power-gravity energy storage integrated system via VSC-HVDC transmission

Xiufang Jia, Jiate Li
IET conference proceedings.
HVDC Systems and Fault Protection
article

Low voltage ride-through strategy for sending-end AC faults in a wind power-gravity energy storage integrated system via VSC-HVDC transmission

Xiufang Jia, Jiate Li
article en

Abstract

Flexible HVDC transmission based on modular multilevel converters (MMCs) is a mainstream solution for integrating large-scale wind power over long distances. However, the sending end of such systems lacks strong grid support, making it susceptible to overvoltage and overcurrent issues during asymmetric AC faults. This paper investigates the transient characteristics and control strategies for such faults in an MMC-HVDC system integrated with gravity energy storage (GES) on the wind farm side. The limitations of conventional negative-sequence current suppression strategies are analysed, highlighting their tendency to cause overvoltage in healthy phases and delayed post-fault voltage recovery. An optimised negative-sequence current control strategy is proposed, wherein the sending-end MMC proactively injects a controlled amount of negative-sequence current to limit fault current magnitude. This is synergised with the rapid power support capability of the GES to facilitate voltage recovery. Simulation results conducted in PSCAD/EMTDC validate the effectiveness and superiority of the proposed strategy in enhancing the system's fault ride-through capability.

IET conference proceedings.Vol. 2025(49)
North China Electric Power University (CN), State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources
Affordable and clean energy
Openalex Percentile: Top 10%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.