ABSTRACT NUMBER: ESOC2026LB85 CEREBRAL EMBOLIC PROTECTION DEVICES (CEPDS) DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI): A META-ANALYSIS OF 11,589 PATIENTS FROM RANDOMIZED CONTROLLED TRIALS.

Abstract Background and aims Transcatheter aortic valve implantation (TAVI) is associated with procedure-related stroke. Cerebral embolic protection devices (CEPDs) are designed to reduce the risk of embolic debris reaching the brain; however, the evidence supporting their efficacy remains controversial. In this study, we aim to evaluate the efficacy and safety of CEPDs in patients undergoing TAVI. Methods Six databases (PubMed, Scopus, Web of Science, Cochrane, Embase, and Ovid) were systematically searched up to April 4, 2025. Only randomized controlled trials (RCTs) were included and critically appraised using the Cochrane Risk of Bias 2 (ROB-2) tool. Statistical analyses were performed using R software to calculate risk ratios (RRs) with 95% confidence intervals. Results We retrieved 1609 records. Eight RCTs (11,589 patients) were analyzed. No significant difference was observed in overall stroke incidence between CEPD and control groups (RR 0.93; 95% CI: 0.74–1.16; P=0.49), including disabling and non-disabling strokes. Device-specific analyses showed a non-significant trend toward reduced disabling stroke with the Sentinel device, while the Triguard device was associated with increased major vascular complications (RR 2.18; 95% CI: 1.04–4.59). All-cause mortality, transient ischemic attacks, bleeding, acute kidney injury, delirium, and pacemaker implantation rates were similar between groups. Notably, CEPD use was linked to a transient improvement in cognitive function (MoCA scores) at 2–5 days post-TAVI, but this effect was not sustained at later follow-ups. Conclusions CEPDs show no significant reduction in overall, disabling, or non-disabling stroke, nor in all-cause mortality post-TAVI. Conflict of interest

Authors

Institutions

Publication Details

Journal
European Stroke Journal
Published
2026-05-01
DOI
https://doi.org/10.1093/esj/aakag023.1944
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ABSTRACT NUMBER: ESOC2026LB85 CEREBRAL EMBOLIC PROTECTION DEVICES (CEPDS) DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI): A META-ANALYSIS OF 11,589 PATIENTS FROM RANDOMIZED CONTROLLED TRIALS.

Ahmed Badran, Mahmoud Balata, Mohamed Gbreel, Marwa Hassan
European Stroke Journal
Cardiac Valve Diseases and Treatments
article

ABSTRACT NUMBER: ESOC2026LB85 CEREBRAL EMBOLIC PROTECTION DEVICES (CEPDS) DURING TRANSCATHETER AORTIC VALVE IMPLANTATION (TAVI): A META-ANALYSIS OF 11,589 PATIENTS FROM RANDOMIZED CONTROLLED TRIALS.

Ahmed Badran, Mahmoud Balata, Mohamed Gbreel, Marwa Hassan
article en

Abstract

Abstract Background and aims Transcatheter aortic valve implantation (TAVI) is associated with procedure-related stroke. Cerebral embolic protection devices (CEPDs) are designed to reduce the risk of embolic debris reaching the brain; however, the evidence supporting their efficacy remains controversial. In this study, we aim to evaluate the efficacy and safety of CEPDs in patients undergoing TAVI. Methods Six databases (PubMed, Scopus, Web of Science, Cochrane, Embase, and Ovid) were systematically searched up to April 4, 2025. Only randomized controlled trials (RCTs) were included and critically appraised using the Cochrane Risk of Bias 2 (ROB-2) tool. Statistical analyses were performed using R software to calculate risk ratios (RRs) with 95% confidence intervals. Results We retrieved 1609 records. Eight RCTs (11,589 patients) were analyzed. No significant difference was observed in overall stroke incidence between CEPD and control groups (RR 0.93; 95% CI: 0.74–1.16; P=0.49), including disabling and non-disabling strokes. Device-specific analyses showed a non-significant trend toward reduced disabling stroke with the Sentinel device, while the Triguard device was associated with increased major vascular complications (RR 2.18; 95% CI: 1.04–4.59). All-cause mortality, transient ischemic attacks, bleeding, acute kidney injury, delirium, and pacemaker implantation rates were similar between groups. Notably, CEPD use was linked to a transient improvement in cognitive function (MoCA scores) at 2–5 days post-TAVI, but this effect was not sustained at later follow-ups. Conclusions CEPDs show no significant reduction in overall, disabling, or non-disabling stroke, nor in all-cause mortality post-TAVI. Conflict of interest

European Stroke JournalVol. 11(Supplement_1)
Ain Shams University (EG), New Cairo Academy (EG), University of Rostock (DE), Theodor Bilharz Research Institute (EG)
Good health and well-being
Openalex Percentile: Top 9%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.