ABSTRACT NUMBER: ESOC2026A2223 EXTRACRANIAL DOPPLER ULTRASOUND HEMODYNAMIC PATTERNS ASSOCIATED WITH CARDIAC VALVULOPATHIES

Abstract Background and aims Extracranial Doppler ultrasound (EDU) is widely used in stroke assessment, but whether carotid flow patterns reflect cardiac valvular disease is not established We aimed to identify Doppler hemodynamic patterns associated with valvulopathies and related markers. Methods Retrospective study of consecutive patients undergoing EDU with transthoracic echocardiography. Patients with moderate-to-severe aortic or mitral stenosis or regurgitation were compared with controls without known valvular disease, matched for age, sex, and hypertension. Doppler parameters (end-diastolic-velocity [EDV], resistance index [RI], acceleration-time [AT], and waveform morphology) were analysed in the common (CCA) and internal carotid arteries (ICA). Results We included 100 patients with valvular disease (35 aortic stenosis, 25 aortic regurgitation, 25 mitral regurgitation, 15 mitral stenosis) and 100 controls. Compared with controls, aortic regurgitation was associated with reduced EDV and increased RI in both CCA (5.6 vs 12.3cm's; 0.92 vs 0.78) and ICA (8.4 vs 17.9cm's; 0.85 vs 0.69; p<0.001). Biphasic waveforms (34% vs 0%) and shorter AT were more frequent in regurgitation (p<0.001). Aortic stenosis showed lower ICA-EDV, parvus–tardus waveforms (69% vs 8%) and prolonged AT (p<0.001). Regurgitations lesions demonstrated lower EDV (p<0.001) and higher RI (p=0.007) than stenotic. In stenosis, smaller valve area and lower ejection-fraction correlated with higher ICA-RI (p=0.031; p<0.001); in regurgitations, ejection-fraction correlated inversely with CCA-AT (p=0.044), and left atrial size correlated with RI (p=0.018). Conclusions Recognising low-EDV/high-RI with shorter-AT and biphasic morphology as suggestive of regurgitation and prolonged AT with parvus–tardus pattern as suggestive of stenosis, may help raise suspicion of relevant valvular disease during routine stroke assessment. Conflict of interest All authors: Nothing to disclose

Authors

Institutions

Publication Details

Journal
European Stroke Journal
Published
2026-05-01
DOI
https://doi.org/10.1093/esj/aakag023.1027
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ABSTRACT NUMBER: ESOC2026A2223 EXTRACRANIAL DOPPLER ULTRASOUND HEMODYNAMIC PATTERNS ASSOCIATED WITH CARDIAC VALVULOPATHIES

Mariana Santos, Lénia Silva, F M Costa, Denis Gabriel et al.
European Stroke Journal
Cerebrovascular and Carotid Artery Diseases
article

ABSTRACT NUMBER: ESOC2026A2223 EXTRACRANIAL DOPPLER ULTRASOUND HEMODYNAMIC PATTERNS ASSOCIATED WITH CARDIAC VALVULOPATHIES

Mariana Santos, Lénia Silva, F M Costa, Denis Gabriel, Rui Felgueiras, R Domingos Da Costa Lopes, Ricardo Varela, Maria Carlos Pereira, Gabriela Lopes, Carolina Gonçalves
article en

Abstract

Abstract Background and aims Extracranial Doppler ultrasound (EDU) is widely used in stroke assessment, but whether carotid flow patterns reflect cardiac valvular disease is not established We aimed to identify Doppler hemodynamic patterns associated with valvulopathies and related markers. Methods Retrospective study of consecutive patients undergoing EDU with transthoracic echocardiography. Patients with moderate-to-severe aortic or mitral stenosis or regurgitation were compared with controls without known valvular disease, matched for age, sex, and hypertension. Doppler parameters (end-diastolic-velocity [EDV], resistance index [RI], acceleration-time [AT], and waveform morphology) were analysed in the common (CCA) and internal carotid arteries (ICA). Results We included 100 patients with valvular disease (35 aortic stenosis, 25 aortic regurgitation, 25 mitral regurgitation, 15 mitral stenosis) and 100 controls. Compared with controls, aortic regurgitation was associated with reduced EDV and increased RI in both CCA (5.6 vs 12.3cm's; 0.92 vs 0.78) and ICA (8.4 vs 17.9cm's; 0.85 vs 0.69; p<0.001). Biphasic waveforms (34% vs 0%) and shorter AT were more frequent in regurgitation (p<0.001). Aortic stenosis showed lower ICA-EDV, parvus–tardus waveforms (69% vs 8%) and prolonged AT (p<0.001). Regurgitations lesions demonstrated lower EDV (p<0.001) and higher RI (p=0.007) than stenotic. In stenosis, smaller valve area and lower ejection-fraction correlated with higher ICA-RI (p=0.031; p<0.001); in regurgitations, ejection-fraction correlated inversely with CCA-AT (p=0.044), and left atrial size correlated with RI (p=0.018). Conclusions Recognising low-EDV/high-RI with shorter-AT and biphasic morphology as suggestive of regurgitation and prolonged AT with parvus–tardus pattern as suggestive of stenosis, may help raise suspicion of relevant valvular disease during routine stroke assessment. Conflict of interest All authors: Nothing to disclose

European Stroke JournalVol. 11(Supplement_1)
Administração Regional de Saúde de Lisboa e Vale do Tejo (PT), Hospital de Santo António (PT)
Openalex Percentile: Top 10%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.