Analysis of protection operation for ultra-high voltage multi-terminal hybrid flexible DC transmission projects

As an important safety barrier in EHV multi terminal hybrid flexible DC transmission system, DC overvoltage protection ensures the safe, reliable and stable operation of the whole multi terminal DC transmission project. In this context, ± 800kV kunbei converter station, as the first transmission station of UHV multi terminal hybrid flexible DC transmission project, its operation status directly affects the safety and efficiency of the whole power grid. However, in the actual operation process, the DC overvoltage open circuit protection of the converter station has abnormal action. In this paper, the cause of the abnormal action is systematically explored through fault recording data tracking, protection logic simulation verification, and field test. On this basis, targeted optimization strategies and improvement measures are proposed.

Authors

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2026-05-01
DOI
https://doi.org/10.1049/icp.2026.0684
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of protection operation for ultra-high voltage multi-terminal hybrid flexible DC transmission projects

Zha Liyun, Shan Shi, Tang Tiejun, Zhang Qiang et al.
IET conference proceedings.
HVDC Systems and Fault Protection
article

Analysis of protection operation for ultra-high voltage multi-terminal hybrid flexible DC transmission projects

Zha Liyun, Shan Shi, Tang Tiejun, Zhang Qiang, Su Zhilong, Lian Xinwen
article en

Abstract

As an important safety barrier in EHV multi terminal hybrid flexible DC transmission system, DC overvoltage protection ensures the safe, reliable and stable operation of the whole multi terminal DC transmission project. In this context, ± 800kV kunbei converter station, as the first transmission station of UHV multi terminal hybrid flexible DC transmission project, its operation status directly affects the safety and efficiency of the whole power grid. However, in the actual operation process, the DC overvoltage open circuit protection of the converter station has abnormal action. In this paper, the cause of the abnormal action is systematically explored through fault recording data tracking, protection logic simulation verification, and field test. On this basis, targeted optimization strategies and improvement measures are proposed.

IET conference proceedings.Vol. 2025(49)
Yunnan Environmental Protection Bureau (CN)
Openalex Percentile: Top 10%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.