Outcomes of greater trochanteric reattachment with a washer in abductor mechanism repair for proximal femur endoprosthetic replacement: A retrospective cohort study

Proximal femur replacement (PFR) following oncological resections necessitates the reconstruction of the abductor mechanism, particularly through the reattachment of the greater trochanter (GT) to the endoprosthesis. This study aim is to assess radiological failure rates associated with the use of GT washer in Zimmer® Segmental System to achieve GT reattachment to the endoprosthesis. A retrospective review was conducted on patient records from 2010 to 2023 from our regional tumour unit in the West of Scotland. Included were patients who underwent PFR for malignancies and had GT reattachment using the GT washer in Zimmer® Segmental System. Patient data from electronic health records and the national PACS system were analysed to assess the radiological outcomes. The cohort comprised 22 patients, with ages ranging from 33 to 81 years (average 60.5 years) and follow-up periods spanning from 1.8 to 107.8 months (average 30.2 months). The interval between the last x-ray and the operation ranged from 3 to 66 months (average 20 months). Radiological evaluation showed a 0% failure rate of GT reattachment at the time of the last AP x-ray and/or outpatient visit. Various methods are available for GT reinsertion into the endoprosthesis, including washers, cables, and direct suturing. Our findings suggest that GT washers in the Zimmer system provide effective GT stabilization without migration, maintaining the integrity of the hip’s abductor musculature. Further comparative studies are necessary to determine the functional outcomes and advantages of each technique to enhance recovery and mobility in PFR patients.

Authors

Institutions

Publication Details

Journal
Journal of Orthopaedic Reports
Published
2026-05-01
DOI
https://doi.org/10.1016/j.jorep.2026.101018
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outcomes of greater trochanteric reattachment with a washer in abductor mechanism repair for proximal femur endoprosthetic replacement: A retrospective cohort study

Waleed Ahsan, Tareq Altell, Ewen Fraser, Ashish Mahendra et al.
Journal of Orthopaedic Reports
Orthopaedic implants and arthroplasty
article

Outcomes of greater trochanteric reattachment with a washer in abductor mechanism repair for proximal femur endoprosthetic replacement: A retrospective cohort study

Waleed Ahsan, Tareq Altell, Ewen Fraser, Ashish Mahendra, Sanjay Gupta
article en

Abstract

Proximal femur replacement (PFR) following oncological resections necessitates the reconstruction of the abductor mechanism, particularly through the reattachment of the greater trochanter (GT) to the endoprosthesis. This study aim is to assess radiological failure rates associated with the use of GT washer in Zimmer® Segmental System to achieve GT reattachment to the endoprosthesis. A retrospective review was conducted on patient records from 2010 to 2023 from our regional tumour unit in the West of Scotland. Included were patients who underwent PFR for malignancies and had GT reattachment using the GT washer in Zimmer® Segmental System. Patient data from electronic health records and the national PACS system were analysed to assess the radiological outcomes. The cohort comprised 22 patients, with ages ranging from 33 to 81 years (average 60.5 years) and follow-up periods spanning from 1.8 to 107.8 months (average 30.2 months). The interval between the last x-ray and the operation ranged from 3 to 66 months (average 20 months). Radiological evaluation showed a 0% failure rate of GT reattachment at the time of the last AP x-ray and/or outpatient visit. Various methods are available for GT reinsertion into the endoprosthesis, including washers, cables, and direct suturing. Our findings suggest that GT washers in the Zimmer system provide effective GT stabilization without migration, maintaining the integrity of the hip’s abductor musculature. Further comparative studies are necessary to determine the functional outcomes and advantages of each technique to enhance recovery and mobility in PFR patients.

Journal of Orthopaedic Reports
Glasgow Royal Infirmary (GB)
Reduced inequalities
Openalex Percentile: Top 10%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Outcomes of greater trochanteric reattachment with a washer in abductor mechanism repair for proximal femur endoprosthetic replacement: A retrospective cohort study — Waleed Ahsan, Tareq Altell, et al. · Journal of Orthopaedic Reports (2026) | TGRS Research Map | TGRS