Preparation of volatile halogenated hydrocarbons reference material and development of analytical methods by dual-inlet internal-standard GC-MS and GC-ECD

In recent decades, environmental concern over volatile halogenated hydrocarbons (VHHs) in ambient air has grown significantly, driven by their widespread occurrence and potential risks to ecosystems and human health. Monitoring VHHs is essential to assess atmospheric pollution, enable risk assessment and guide regulatory decisions. However, as VHHs concentrations vary widely in ambient air, their accurate quantification necessitates multi-level reference materials (RMs) coupled with highly sensitive and precise analytical methods. Existing single-level RMs fail to cover the concentration gradients present in stack emissions, risking the absence of a traceability chain. Although GC-MS is a commonly used monitoring instrument, it suffers from signal drift (i.e., gradually decreasing response values) during experiments, which can compromise data accuracy. The study selected 14 VHHs that are under key monitoring in China, with concentrations relevant to current emission control requirements. The 14 VHHs RMs with a multi-concentration level ranging from 0.01 μmol/mol to 50 μmol/mol were first prepared using a gravimetric approach with reasonable grouping, separate weighing and final combination preparation. A novel dual-inlet internal-standard GC-MS analytical method and a GC-ECD analytical method were developed for the determination of the 14 VHHs RMs. The resolution, asymmetry and sensitivity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy were validated. The results showed that both methods effectively separated the 14 VHH RMs, with LODs of 0.1 nmol/mol–1.51 nmol/mol for GC-MS and 0.02 nmol/mol–4.9 nmol/mol for GC-ECD. Both methods exhibited excellent linearity, with correlation coefficients >0.995 for all calibration curves. Regarding repeatability (RSD), the system, method, and intermediate variabilities were ≤0.75%, ≤0.90%, and ≤1.09% for GC-MS, and ≤0.66%, ≤0.82%, and ≤0.92% for GC-ECD. The results indicated that the developed VHHs RMs with the GC-MS and GC-ECD analytical methods were expected to be used for ambient air monitoring and stationary source emission monitoring. • 14 volatile halogenated hydrocarbons (VHHs) reference materials (RMs) were prepared for the first time. • A novel dual-inlet internal-standard GC-MS configuration and GC-ECD were developed to determine the 14 VHHs. • The GC-MS and GC-ECD method were validated, demonstrating their good performance. • The developed VHHs RMs with GC-MS and GC-ECD methods can be used for fixed pollution source exhaust gas monitoring.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Materials Organics
Published
2026-05-01
DOI
https://doi.org/10.1016/j.hazmo.2026.100028
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Preparation of volatile halogenated hydrocarbons reference material and development of analytical methods by dual-inlet internal-standard GC-MS and GC-ECD

Bing Gao, Tao Liu, Jing Yang, Peng Qiu et al.
Journal of Hazardous Materials Organics
Analytical chemistry methods development
article

Preparation of volatile halogenated hydrocarbons reference material and development of analytical methods by dual-inlet internal-standard GC-MS and GC-ECD

Bing Gao, Tao Liu, Jing Yang, Peng Qiu, Hongwei Hao, Wei Huang, Jian Du
article en

Abstract

In recent decades, environmental concern over volatile halogenated hydrocarbons (VHHs) in ambient air has grown significantly, driven by their widespread occurrence and potential risks to ecosystems and human health. Monitoring VHHs is essential to assess atmospheric pollution, enable risk assessment and guide regulatory decisions. However, as VHHs concentrations vary widely in ambient air, their accurate quantification necessitates multi-level reference materials (RMs) coupled with highly sensitive and precise analytical methods. Existing single-level RMs fail to cover the concentration gradients present in stack emissions, risking the absence of a traceability chain. Although GC-MS is a commonly used monitoring instrument, it suffers from signal drift (i.e., gradually decreasing response values) during experiments, which can compromise data accuracy. The study selected 14 VHHs that are under key monitoring in China, with concentrations relevant to current emission control requirements. The 14 VHHs RMs with a multi-concentration level ranging from 0.01 μmol/mol to 50 μmol/mol were first prepared using a gravimetric approach with reasonable grouping, separate weighing and final combination preparation. A novel dual-inlet internal-standard GC-MS analytical method and a GC-ECD analytical method were developed for the determination of the 14 VHHs RMs. The resolution, asymmetry and sensitivity, linearity, limit of detection (LOD), limit of quantification (LOQ), precision, and accuracy were validated. The results showed that both methods effectively separated the 14 VHH RMs, with LODs of 0.1 nmol/mol–1.51 nmol/mol for GC-MS and 0.02 nmol/mol–4.9 nmol/mol for GC-ECD. Both methods exhibited excellent linearity, with correlation coefficients >0.995 for all calibration curves. Regarding repeatability (RSD), the system, method, and intermediate variabilities were ≤0.75%, ≤0.90%, and ≤1.09% for GC-MS, and ≤0.66%, ≤0.82%, and ≤0.92% for GC-ECD. The results indicated that the developed VHHs RMs with the GC-MS and GC-ECD analytical methods were expected to be used for ambient air monitoring and stationary source emission monitoring. • 14 volatile halogenated hydrocarbons (VHHs) reference materials (RMs) were prepared for the first time. • A novel dual-inlet internal-standard GC-MS configuration and GC-ECD were developed to determine the 14 VHHs. • The GC-MS and GC-ECD method were validated, demonstrating their good performance. • The developed VHHs RMs with GC-MS and GC-ECD methods can be used for fixed pollution source exhaust gas monitoring.

Journal of Hazardous Materials Organics
Ministry of Ecology and Environment (CN)
Openalex Percentile: Top 9%
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.