Imaging of Artificial Tumor Models in an Anatomical Breast Phantom with a Single-Sided Magnetic Particle Imaging Scanner

Background: Magnetic Particle Imaging (MPI) is an emerging biomedical imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIONs), providing high contrast, sensitivity, and quantification capabilities without ionizing radiation, making it particularly suitable for cancer diagnostics. Considerable engineering efforts are underway to translate MPI technology to clinical settings. Most of these MPI scanners feature a cylindrical bore geometry similar to that of other clinical imaging modalities, which limits their potential application primarily to head scanning. Methods: We have developed a single-sided MPI scanner designed to expand the modality’s applicability to other regions of the human body through a unique hardware design developed in our previous work. Imaging experiments were performed on an anatomical breast phantom containing implanted SPION point sources placed at anatomically plausible locations for breast tumors. These point sources served as artificial tumors for evaluating the system’s suitability for breast imaging applications. Results: The scanner successfully detected and clearly resolved the implanted SPION tumors in two orthogonal imaging planes. Tumor positioning was independently validated by ultrasound imaging, confirming MPI’s accurate localization. In addition, sensitivity measurements demonstrated a detection limit of 4.0 μg of iron, below the estimated 4.8 μg sensitivity threshold required for breast tumor detection with electronic depth scanning up to 3.5 cm deep. Conclusions: Together, these results demonstrate the capability of a single-sided MPI geometry for breast imaging applications. Imaging an anatomical breast-shaped volume presents significant challenges for MPI due to the size and accessibility constraints of conventional hardware. The results presented highlight the advantages of this approach and support its potential to extend MPI from small-animal imaging to clinically relevant applications.

Authors

Institutions

Publication Details

Journal
Tomography
Published
2026-04-24
DOI
https://doi.org/10.3390/tomography12050060
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Imaging of Artificial Tumor Models in an Anatomical Breast Phantom with a Single-Sided Magnetic Particle Imaging Scanner

Chris McDonough, Alycen Wiacek, John Chrisekos, Matthew Jurj et al.
Tomography
Characterization and Applications of Magnetic Nanoparticles
article

Imaging of Artificial Tumor Models in an Anatomical Breast Phantom with a Single-Sided Magnetic Particle Imaging Scanner

Chris McDonough, Alycen Wiacek, John Chrisekos, Matthew Jurj, Alexey Tonyushkin
article en

Abstract

Background: Magnetic Particle Imaging (MPI) is an emerging biomedical imaging modality that detects superparamagnetic iron oxide nanoparticles (SPIONs), providing high contrast, sensitivity, and quantification capabilities without ionizing radiation, making it particularly suitable for cancer diagnostics. Considerable engineering efforts are underway to translate MPI technology to clinical settings. Most of these MPI scanners feature a cylindrical bore geometry similar to that of other clinical imaging modalities, which limits their potential application primarily to head scanning. Methods: We have developed a single-sided MPI scanner designed to expand the modality’s applicability to other regions of the human body through a unique hardware design developed in our previous work. Imaging experiments were performed on an anatomical breast phantom containing implanted SPION point sources placed at anatomically plausible locations for breast tumors. These point sources served as artificial tumors for evaluating the system’s suitability for breast imaging applications. Results: The scanner successfully detected and clearly resolved the implanted SPION tumors in two orthogonal imaging planes. Tumor positioning was independently validated by ultrasound imaging, confirming MPI’s accurate localization. In addition, sensitivity measurements demonstrated a detection limit of 4.0 μg of iron, below the estimated 4.8 μg sensitivity threshold required for breast tumor detection with electronic depth scanning up to 3.5 cm deep. Conclusions: Together, these results demonstrate the capability of a single-sided MPI geometry for breast imaging applications. Imaging an anatomical breast-shaped volume presents significant challenges for MPI due to the size and accessibility constraints of conventional hardware. The results presented highlight the advantages of this approach and support its potential to extend MPI from small-animal imaging to clinically relevant applications.

TomographyVol. 12(5)
Oakland University (US)
National Institutes of Health, National Institute of Biomedical Imaging and Bioengineering
Openalex Percentile: Top 11%
Characterization and Applications of Magnetic Nanoparticles
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.