Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters

The increasing integration of nonlinear loads in modern power systems has made harmonic pollution a critical challenge to the operational safety of power cables. This study develops a frequency-dependent high-voltage cable system model using the ATP-EMTP (Alternative Transients Program-Electro Magnetic Transient Program) electromagnetic transient simulation platform, systematically investigating the amplification mechanisms and propagation characteristics of grounding currents under multi-type harmonic disturbances. A frequency-dependent parameter correction model is established by integrating the conductor skin effect and the dielectric relaxation properties of the insulation layers. This model incorporates the multi-structure combination among conductors, insulation, and metallic screen. It effectively overcomes the limitations of conventional lumped-parameter models in higher frequency harmonic analysis. Key findings are as follows: (1) The combined influence of harmonic frequency and amplitude leads to a grounding current amplification of up to 445 times (at 1950 Hz with 30% distortion level). Notably, current-source excitation produces significantly greater amplification than voltage-source excitation. (2) The distributed capacitance of long-distance cables (>8 km) exacerbates resonance risks within specific frequency bands (750–1250 Hz), resulting in a maximum harmonic amplification factor of 34.73 (observed for the 17th harmonic in a 15 km cable). (3) The contribution of voltage-source harmonics diminishes to less than 5% of the total current at high frequencies (≥1250 Hz), indicating a pattern of current-dominated harmonic superposition.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2026-04-24
DOI
https://doi.org/10.3390/app16094202
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters

Xiaoyi Cheng, Ge Wang, Yuli Wang, Yan Zhang et al.
Applied Sciences
Lightning and Electromagnetic Phenomena
article

Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters

Xiaoyi Cheng, Ge Wang, Yuli Wang, Yan Zhang, Zhaoyu Qin
article en

Abstract

The increasing integration of nonlinear loads in modern power systems has made harmonic pollution a critical challenge to the operational safety of power cables. This study develops a frequency-dependent high-voltage cable system model using the ATP-EMTP (Alternative Transients Program-Electro Magnetic Transient Program) electromagnetic transient simulation platform, systematically investigating the amplification mechanisms and propagation characteristics of grounding currents under multi-type harmonic disturbances. A frequency-dependent parameter correction model is established by integrating the conductor skin effect and the dielectric relaxation properties of the insulation layers. This model incorporates the multi-structure combination among conductors, insulation, and metallic screen. It effectively overcomes the limitations of conventional lumped-parameter models in higher frequency harmonic analysis. Key findings are as follows: (1) The combined influence of harmonic frequency and amplitude leads to a grounding current amplification of up to 445 times (at 1950 Hz with 30% distortion level). Notably, current-source excitation produces significantly greater amplification than voltage-source excitation. (2) The distributed capacitance of long-distance cables (>8 km) exacerbates resonance risks within specific frequency bands (750–1250 Hz), resulting in a maximum harmonic amplification factor of 34.73 (observed for the 17th harmonic in a 15 km cable). (3) The contribution of voltage-source harmonics diminishes to less than 5% of the total current at high frequencies (≥1250 Hz), indicating a pattern of current-dominated harmonic superposition.

Applied SciencesVol. 16(9)
China Electric Power Research Institute, Hubei University of Technology (CN)
Electric Power Research Institute, China Electric Power Research Institute
Affordable and clean energy
Openalex Percentile: Top 7%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Harmonic Resonance Mechanism and Suppression Strategies for High-Voltage Cables with Frequency-Dependent Parameters — Xiaoyi Cheng, Ge Wang, et al. · Applied Sciences (2026) | TGRS Research Map | TGRS