Study of hosting capacity for harmonic distortion and resonance in transmission networks under large-scale wind and PV integration: A Python-based Monte Carlo simulation analysis

The increasing penetration of converter-interfaced renewable energy sources (RES) significantly alters the harmonic behavior and frequency-dependent impedance characteristics of transmission networks, posing challenges to power quality and system reliability. This paper proposes a probabilistic harmonic hosting capacity approach for transmission-level systems by integrating Monte Carlo–based uncertainty propagation with frequency-domain modeling in DIgSILENT PowerFactory. Unlike previous studies, the proposed method explicitly incorporates stochastic variations in operating conditions and resonance-sensitive impedance characteristics at the transmission level. The methodology is applied to a 110 kV transmission network, considering multiple points of common coupling with wind and photovoltaic plants under different penetration levels. The results indicate that smaller wind installations maintain total harmonic distortion (THD) within acceptable limits (1.51%), allowing additional integration capacity, whereas larger wind plants approach and exceed the 2% limit (2.56%), indicating reduced hosting capacity. In contrast, PV plants exhibit higher distortion levels (3.19%) and lower hosting margins, reflecting stronger sensitivity to impedance variations and resonance effects. Overall, the study demonstrates that harmonic hosting capacity is strongly governed by converter characteristics, installed capacity, and resonance-sensitive impedance behavior, and enables a risk-based probabilistic assessment of harmonic compliance for planning transmission systems with high shares of inverter-based generation.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2026-09-01
DOI
https://doi.org/10.1016/j.rineng.2026.112725
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
article

Study of hosting capacity for harmonic distortion and resonance in transmission networks under large-scale wind and PV integration: A Python-based Monte Carlo simulation analysis

Petrit Emini, Dimitar Dimitrov
Results in Engineering
Optimal Power Flow Distribution
article

Study of hosting capacity for harmonic distortion and resonance in transmission networks under large-scale wind and PV integration: A Python-based Monte Carlo simulation analysis

Petrit Emini, Dimitar Dimitrov
article en

Abstract

The increasing penetration of converter-interfaced renewable energy sources (RES) significantly alters the harmonic behavior and frequency-dependent impedance characteristics of transmission networks, posing challenges to power quality and system reliability. This paper proposes a probabilistic harmonic hosting capacity approach for transmission-level systems by integrating Monte Carlo–based uncertainty propagation with frequency-domain modeling in DIgSILENT PowerFactory. Unlike previous studies, the proposed method explicitly incorporates stochastic variations in operating conditions and resonance-sensitive impedance characteristics at the transmission level. The methodology is applied to a 110 kV transmission network, considering multiple points of common coupling with wind and photovoltaic plants under different penetration levels. The results indicate that smaller wind installations maintain total harmonic distortion (THD) within acceptable limits (1.51%), allowing additional integration capacity, whereas larger wind plants approach and exceed the 2% limit (2.56%), indicating reduced hosting capacity. In contrast, PV plants exhibit higher distortion levels (3.19%) and lower hosting margins, reflecting stronger sensitivity to impedance variations and resonance effects. Overall, the study demonstrates that harmonic hosting capacity is strongly governed by converter characteristics, installed capacity, and resonance-sensitive impedance behavior, and enables a risk-based probabilistic assessment of harmonic compliance for planning transmission systems with high shares of inverter-based generation.

Results in Engineering
University of Prishtina (XK)
Affordable and clean energy
Openalex Percentile: Top 67%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study of hosting capacity for harmonic distortion and resonance in transmission networks under large-scale wind and PV integration: A Python-based Monte Carlo simulation analysis — Petrit Emini, Dimitar Dimitrov · Results in Engineering (2026) | TGRS Research Map | TGRS