Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection

Rapid antigen tests targeting SARS-CoV-2 nucleocapsid protein were essential for decentralised testing during the COVID-19 pandemic. Independent performance evaluations are essential to support regulatory approval and inform clinical implementation, particularly in resource-limited settings. This study presents a retrospective analytical and operational evaluation of two instrument-based fluorescent immunoassays (FIAs): the PCL COVID-19 Ag Rapid FIA and LumiraDx SARS-CoV-2 Ag Test. Analytical sensitivity was determined using recombinant nucleocapsid protein and viral cultures. Clinical performance was assessed using residual clinical specimens (n = 110) with RT-PCR as a reference, stratified by cycle threshold (Ct). Operational characteristics were assessed using a structured Likert framework. Overall sensitivity was 63% (51–73) for PCL and 95% (88–99) for LumiraDx. For Ct ≤ 25, sensitivity increased to 93% and 100%. Specificity was ≥97% for both. LumiraDx maintained sensitivity (83–94%) at Ct 25–30, whereas PCL did not detect any positives in this range. The limit of detection was 39 pM (PCL) and 0.6 pM (LumiraDx). Operational usability was high for both (90% PCL, 87% LumiraDx). LumiraDx showed higher analytical sensitivity across a broader viral load range, supporting primary diagnostic use, whereas PCL was limited to high viral loads. This evaluation provides a reproducible framework for rapid diagnostic assessment during emerging outbreaks.

Authors

Institutions

Publication Details

Journal
COVID
Published
2026-04-30
DOI
https://doi.org/10.3390/covid6050078
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection

Vidya Keshav, Lucia Hans, Lesley Scott, Wendy Stevens
COVID
SARS-CoV-2 detection and testing
article

Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection

Vidya Keshav, Lucia Hans, Lesley Scott, Wendy Stevens
article en

Abstract

Rapid antigen tests targeting SARS-CoV-2 nucleocapsid protein were essential for decentralised testing during the COVID-19 pandemic. Independent performance evaluations are essential to support regulatory approval and inform clinical implementation, particularly in resource-limited settings. This study presents a retrospective analytical and operational evaluation of two instrument-based fluorescent immunoassays (FIAs): the PCL COVID-19 Ag Rapid FIA and LumiraDx SARS-CoV-2 Ag Test. Analytical sensitivity was determined using recombinant nucleocapsid protein and viral cultures. Clinical performance was assessed using residual clinical specimens (n = 110) with RT-PCR as a reference, stratified by cycle threshold (Ct). Operational characteristics were assessed using a structured Likert framework. Overall sensitivity was 63% (51–73) for PCL and 95% (88–99) for LumiraDx. For Ct ≤ 25, sensitivity increased to 93% and 100%. Specificity was ≥97% for both. LumiraDx maintained sensitivity (83–94%) at Ct 25–30, whereas PCL did not detect any positives in this range. The limit of detection was 39 pM (PCL) and 0.6 pM (LumiraDx). Operational usability was high for both (90% PCL, 87% LumiraDx). LumiraDx showed higher analytical sensitivity across a broader viral load range, supporting primary diagnostic use, whereas PCL was limited to high viral loads. This evaluation provides a reproducible framework for rapid diagnostic assessment during emerging outbreaks.

COVIDVol. 6(5)
National Health Laboratory Service (ZA), University of the Witwatersrand (ZA)
Good health and well-being
Openalex Percentile: Top 6%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Performance Evaluation of Instrument-Based SARS-CoV-2 Rapid Antigen Fluorescent Immunoassays for Point-of-Care Detection — Vidya Keshav, Lucia Hans, et al. · COVID (2026) | TGRS Research Map | TGRS