Data Provenance and Whole-Life Carbon Assessment: A Colombian Residential Building Case Study

This study evaluates how differences in data provenance and inventory construction influence whole-life carbon assessment (WLCA) results for a residential building in Colombia. Two scenarios were assessed: Scenario A, based on contractor records (building Company Z) and the public utility supplier; and Scenario B, based on drawing-derived quantity take-offs and a Colombian regulatory energy baseline (Resolution 0549 of 2015). The assessment follows UNE-EN 15978 and Royal Institution of Chartered Surveyors (RICS) WLCA for modules A1–A3, A4–A5, and B6. Scenario B reached 784.4 kg CO2e/m2, which is 37.9% higher than Scenario A. In the product stage, impacts increased from 298.1 to 332.6 kg CO2e/m2, while in the operational energy stage they increased from 246.2 to 426.2 kg CO2e/m2. The results show that WLCA outcomes are highly sensitive to data provenance, reporting gaps, and baseline selection, underscoring the need for stronger data governance and more traceable environmental reporting practices in building assessment.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2026-04-30
DOI
https://doi.org/10.3390/su18094401
Primary Topic
Environmental Impact and Sustainability
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Data Provenance and Whole-Life Carbon Assessment: A Colombian Residential Building Case Study

Jose Zelaya, Nicolas Pardo, Alejandra Rico, Alexander Méndez et al.
Sustainability
Environmental Impact and Sustainability
article

Data Provenance and Whole-Life Carbon Assessment: A Colombian Residential Building Case Study

Jose Zelaya, Nicolas Pardo, Alejandra Rico, Alexander Méndez, Luis Zapata, Kelly Quintero
article en

Abstract

This study evaluates how differences in data provenance and inventory construction influence whole-life carbon assessment (WLCA) results for a residential building in Colombia. Two scenarios were assessed: Scenario A, based on contractor records (building Company Z) and the public utility supplier; and Scenario B, based on drawing-derived quantity take-offs and a Colombian regulatory energy baseline (Resolution 0549 of 2015). The assessment follows UNE-EN 15978 and Royal Institution of Chartered Surveyors (RICS) WLCA for modules A1–A3, A4–A5, and B6. Scenario B reached 784.4 kg CO2e/m2, which is 37.9% higher than Scenario A. In the product stage, impacts increased from 298.1 to 332.6 kg CO2e/m2, while in the operational energy stage they increased from 246.2 to 426.2 kg CO2e/m2. The results show that WLCA outcomes are highly sensitive to data provenance, reporting gaps, and baseline selection, underscoring the need for stronger data governance and more traceable environmental reporting practices in building assessment.

SustainabilityVol. 18(9)
Institución Universitaria Colegio Mayor de Antioquia (CO)
Responsible consumption and production
Openalex Percentile: Top 9%
Environmental Impact and Sustainability
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.